GEN
– 16P – User Manual
Page 10 of 22
INSTRUCTION FOR USE
WARNING
Read and adhere to all safety and operation instructions.
BEFORE USE
Before using the generator, ensure all the safety and operation instructions are read
and the following steps are performed.
OIL LEVEL CHECK
CAUTION
Check the engine oil level with the engine stopped and in a levelled
position
1. Check the engine oil level with the engine stopped and, in a levelled position.
2. Start the engine and let it idle for 1 or 2 minutes. Stop the engine and wait for 2 or 3
minutes.
3. Remove the oil level dipstick and wipe it clean.
4. Fully insert the oil level dipstick, then remove it to check the oil
level.
5. If the oil level is low, remove the oil filler cap, and fill with the
recommended oil to the upper limit mark on the oil level dipstick.
6. Reinstall the oil level dipstick and oil filler cap
NOTE:
New machines will be pre-oiled from MAKINEX with:
Honda Power Equipment Engine Oil
– SAE 10W-30, API SJ