background image

GEN 

– 16P – User Manual 

 

Page 1 of 22 

INTRODUCTION 

Thank you for purchasing a MAKINEX product. 

 

This manual provides information and procedures to safely operate and maintain the 

GEN-16P 

Generator. For your own safety and protection from injury,  carefully read, 

understand, and observe the safety instructions described in this manual.  
 
Keep this manual or a copy of it with the machine. If you lose this manual or need an 
additional  copy,  please  contact  MAKINEX.  This  machine  is  designed  and  built  with 
user  safety  in  mind;  however,  it  can  present  hazards  if  improperly  operated  and 
serviced. If there are any questions regarding operating or servicing of this machine, 
please contact MAKINEX.  
 

All rights, especially copying and distribution rights are reserved.  

Copyright 2019 by MAKINEX. 

 

No part of this publication may be reproduced in any form or by any means, electronic 
or  mechanical,  including  photocopying,  without  express  written  permission  from 
MAKINEX. 
 
Any  type  of  reproduction  or  distribution  not  authorised  by  MAKINEX  represents  an 
infringement of valid copyrights and will be prosecuted. We expressly reserve the right 
to make technical modifications, even without due notice, which aim at improving our 
machines or their safety standards. 

DISCLAIMER 

MAKINEX  and  its  affiliates  take  no  responsibility  for  any  damage,  injury  or  death 
resulting from the incorrect or unsafe use of this product. Use of this product should be 
un

dertaken by competent persons only. It is the operator’s responsibility to ensure that 

the  following  safety  procedures  are  followed.  If  you  are  unsure,  do  not  operate  this 
product. 

Record  the  model  and  serial  numbers  as  well  as  date  and  place  of  purchase  for      
future reference. Have this information available when ordering parts and when making 
technical or warranty inquiries. 

 

 
 

 

 

MAKINEX SUPPORT 

Refer to contact details on pg. 19 

MODEL NO. 

GEN-16P 

SERIAL NO. 

 

DATE OF PURCHASE 

 

PURCHASE LOCATION 

Summary of Contents for GEN-16P

Page 1: ...r OPERATOR S MANUAL Rev 0919 Makinex 16kVA Generator GEN 16P 2x15A 1x20A 3P Outlet 2x15A 1x32A 3P Outlet...

Page 2: ...8 OVERALL MACHINE DIMENSIONS 9 ALTERNATOR SPECIFICATIONS 9 INSTRUCTION FOR USE 10 BEFORE USE 10 OPERATING GENERATOR 12 MAINTENANCE 13 GENERAL RECOMMENDATIONS 13 GENERAL TROUBLESHOOTING 14 STORAGE 15...

Page 3: ...tronic or mechanical including photocopying without express written permission from MAKINEX Any type of reproduction or distribution not authorised by MAKINEX represents an infringement of valid copyr...

Page 4: ...on CAUTION CAUTION indicates a potential hazardous situation which if not avoided may result in minor or moderate injury WARNING WARNING indicates a potentially hazardous situation which if not avoide...

Page 5: ...ALWAYS disconnect the generator when carrying out any maintenance ALWAYS ensure the generator reaches operating speed before connecting a load ALWAYS start the engine BEFORE connecting any appliances...

Page 6: ...leave at least a 1 metre 3 foot gap between the generator and any surrounding building or structure ALWAYS ensure the generator is on a solid flat surface ALWAYS ensure the surrounding area is free f...

Page 7: ...use any damaged electrical cord sets with the generator FIRE RELATED SAFETY PRECAUTIONS DANGER RISK OF EXPLOSION OR FIRE Fuel and its vapours are extremely flammable and explosive Fire or explosion ca...

Page 8: ...TS IF YOU ARE NOT A QUALIFIED ELECTRICIAN ELECTRICAL HAZARD WARNING FAILURE TO PROPERLY CONNECT THE EQUIPMENT TO THE EARTHING CONDUCTOR WILL RESULT IN A RISK OF ELECTROCUTION CONSULT WITH A QUALIFIED...

Page 9: ...GEN 16P User Manual Page 7 of 27 GENERAL SAFETY DECAL 1 4 7 2 5 8 3 6 9 10...

Page 10: ...G DIMENSIONS 772 x 530x 902mm LENGTH x WIDTH x HEIGHT APPROX NOISE LEVEL 7m NO LOAD 72dB 50 LOAD 76dB 100 LOAD 78dB ENGINE TYPE TWIN CYLINDER AIR COOLED PETROL MODEL HONDA GX690 STARTING SYSTEM ELECTR...

Page 11: ...GEN 16P User Manual Page 9 of 22 OVERALL MACHINE DIMENSIONS ALTERNATOR SPECIFICATIONS Dimensions in mm...

Page 12: ...level with the engine stopped and in a levelled position 2 Start the engine and let it idle for 1 or 2 minutes Stop the engine and wait for 2 or 3 minutes 3 Remove the oil level dipstick and wipe it...

Page 13: ...evere burns and even death FIRE HAZARD WARNING Always ensure that fuel tanks are filled outdoors 1 Turn generator OFF and let it cool for at least two minutes before removing fuel cap 2 Loosen fuel ca...

Page 14: ...it there until the engine starts 5 When the engine starts release the engine switch allowing it to return to the ON position 6 Once the engine has warmed up set the choke lever to the OPEN position C...

Page 15: ...intenance schedule is in the Honda GX690 owner s manual Should you have questions about replacing components on your generator please contact dealer for assistance MAKINEX dealers have access to all t...

Page 16: ...lace or clean air filter Generator is overloaded Reduce the load Fault in alternator Contact authorised Makinex dealer Engine throttle is in SLOW position Slide the throttle to FAST position Engine re...

Page 17: ...iefly turn the key starter for 1 2 seconds to distribute oil DO NOT start engine at this time WARNING Unintentional sparking can cause fire or electrical shock Failure to observe this warning can caus...

Page 18: ...tions and exclusions printed on this page This warranty applies only to new MAKINEX generator distributed by us and by our authorised MAKINEX dealers Under the limited warranty and at MAKINEX s discre...

Page 19: ...ved in an accident abused loaded beyond the generator s limits modified and installed improperly Normal maintenance such as spark plugs air filters adjustments fuel system cleaning and obstruction due...

Page 20: ...rised staff or appointed agents at a premise to be determined by the Manufacturer It is the responsibility and cost of MAKINEX or our appointed agent to return the machine to be repaired or replaced u...

Page 21: ...nex com au SERVICE SPARE PARTS WARRANTY EMAIL service makinex com au USA SALES TEL 1 855 625 4639 WEB www makinex com SERVICE SPARE PARTS WARRANTY EMAIL service makinex com UK WEB www makinex co uk EU...

Page 22: ...GEN 16PQ User Manual Page 20 of 28 APPENDICES APPENDIX A WIRING CIRCUIT DIAGRAM...

Page 23: ...GEN 16P User Manual Page 21 of 22 APPENDIX B RISK ASSESSMENT...

Page 24: ...GEN 16P User Manual Page 22 of 22...

Reviews: