3
ENGLISH (Original instructions)
Explanation of general view
1-1. Lever
2-1. Bevel scale plate
2-2. Knob
3-1. Base
3-2. Adjusting screw
4-1. Triangular rule
5-1. Notch
5-2. For 45
゚
bevel cuts
5-3. For straight cuts
6-1. Lock-off button
6-2. Switch trigger
7-1. Dust box
7-2. Screw
8-1. Hex wrench
8-2. Shaft lock
9-1. Diamond wheel
9-2. Outer flange
9-3. Hex socket head bolt
9-4. Inner flange
10-1. Rip fence (Guide rule)
11-1. Dust cap
11-2. Rubber cap
11-3. Lever
12-1. Rear handle
12-2. Front grip
12-3. Base
13-1. Limit mark
14-1. Brush holder cap
14-2. Screwdriver
SPECIFICATIONS
Model 4157KB
Wheel diameter
180 mm
Max. wheel thickness
2.3 mm
90° 58
mm
Max. cutting capacities
45° 29
mm
Rated speed (n) / No load speed (n
0
) 6,200
(min
-1
)
Overall length
354 mm
Net weight
5.6 kg
Safety class
/II
• Due to our continuing program of research and development, the specifications herein are subject to change without notice.
• Specifications may differ from country to country.
• Weight according to EPTA-Procedure 01/2003
END206-6
Symbols
The following show the symbols used for the equipment.
Be sure that you understand their meaning before use.
・
Read instruction manual.
・
DOUBLE
INSULATION
・
Wear
safety
glasses.
・
Do not use the tool upside down.
・
Do not use the abrasive cut-off wheel.
・
Do not use the saw blade and diamond
wheel with grooves and openings.
・
Only for EU countries
Do not dispose of electric equipment
together with household waste
material!
In observance of the European
Directive, on Waste Electric and
Electronic Equipment and its
implementation in accordance with
national law, electric equipment that
have reached the end of their life must
be collected separately and returned to
an environmentally compatible
recycling facility.
ENE024-1
Intended use
The tool is intended for cutting in brick and concrete
without the use of water.
ENF002-2
Power supply
The tool should be connected only to a power supply of
the same voltage as indicated on the nameplate, and
can only be operated on single-phase AC supply. They
are double-insulated and can, therefore, also be used
from sockets without earth wire.
ENF100-1
For public low-voltage distribution systems of
between 220 V and 250 V.
Switching operations of electric apparatus cause voltage
fluctuations. The operation of this device under
unfavorable mains conditions can have adverse effects to
the operation of other equipment. With a mains impedance
equal or less than 0.31 Ohms it can be presumed that
there will be no negative effects. The mains socket used
for this device must be protected with a fuse or protective
circuit breaker having slow tripping characteristics.