Wiring under Switch
Wiring in Handle set (R)
P 1
1
/ 1
4
Pin
Strain relief
Rib
Noise suppressor (with three lead wires)
Noise suppressor (with three lead wires)
and Choke coil are put to the place
as drawn above if they are used.
Connector 2-SD
Route Lead wires under Switch and decentralize
them with the ribs and pins of Housing R.
Noise suppressor’s lead wires ( 3 pcs.) must be beyond Switch trigger by routing between the ribs and the pin
of Handle set R near the upper side of Switch.
Come out at least 15 mm long
of Power supply cord from
Strain relief, and clamp the cord
with Strain relief.
Fig. D-5
Fig. D-6
15 mm
Choke coil
Strain relief
W
iring diagram for 9237C
Route Lead wires under Switch
as drawn in
Fig. 6.
Be careful not to put Lead wires
on the rib for Terminal block setting.
Set Terminal block to Handle
set (R) as drawn in
Fig. D-4
.
Fix the following lead wires
in this Lead wire holder.
* Field lead wire (black)
* Brush holder’s lead wire (orange)
* Grounding lead wire (green)