5.4.
HOUSING SECTION
Figure 48
(6)
Rib C
Projection of Earth terminal
Projection of Earth terminal
Projection of Earth terminal
Earth terminal
(29)
(7)
Line filter
(if used)
Rib D
OK (opposite side of Yoke unit (29))
(29)
OK (Yoke unit (29) side)
Rib B
Boss A
Projection of
Earth terminal
Rib A
Lead wire holder
Area C
(32)
NOK
The projection of Earth terminal (if
used) must be faced to the opposite
side of Yoke unit (29) or Yoke unit
(29) side.
Lead wires of
Brush holder
complete (32)
must be put
into these
Lead wire
holders.
Lead wires of Brush
holder complete (32)
must not be crossed
in this area.
Put Lead wire of
earth terminal (if
used) into this Lead
wire holder.
Do not put Lead
wires on Rib B, Rib
C and Boss A.
(29)
(29)
Put
Non-insulated
connector (for
repairing LED
circuit) and Line
filter protected
by polyolefin
tube into this
area.
Do not put the Lead
wires connected to
Terminal (7) on Rib D.
Do not put Lead wire of
earth terminal (if used)
onto Area C (between Rib A
and Brush holder complete
(32)).
(32)
24 / 27