4. PRE-OPERATION CHECKS
(See Fig. 

3

3

)

1. CHECK ENGINE OIL (See Fig. 

3

3

-

q

q

,

w

w

)

Before checking or refilling oil, be sure generator is
located on stable and level surface with engine stopped.

Remove oil filler cap and check the engine oil level.

If oil level is below the lower level line, refill
with suitable oil (see table) to upper level line.
Do not screw in the oil filler cap when
checking oil level.

Change oil if contaminated.
(See "How-To" Maintenance.)

Oil capacity . . . .  0.4 liters (0.42 qts)

2. CHECK ENGINE FUEL (SeeFig. 

2

2

-

o

o

3

3

-

e

e

)

If fuel level is low, refill with unleaded
automotive gasoline.

Fuel level should never over the RED marking
at the inlet portion. (SeeFig. 

3

3

-

e

e

-

q

)

q

RED MARKING

Be sure to use the fuel filter screen on the fuel
filter neck.

q

FUEL TANK CAP

w

FUEL FILTER SCREEN

e

TANK CAP COVER

Fuel tank capacity   . . . 3.5 liters (0.92 US.gal)

When using the generator first time or stopping
due the fuel running out, pull the recoil handle
several times after filling fuel up to the RED
marking at the inlet portion of the fuel tank.

Recommended engine oil:

Use 4-stroke automotive detergent oil of API service class
SE or higher grade (SG, SH or SJ is recommended).
SAE 10W-30 or 10W-40 is recommended for
general, all-temperature use. If single viscosity oil is
used, select the appropriate viscosity for the
average temperature in your area.

Ambient
temperature

Single grade

Multigrade

5W

10W

20W

#20

#30

#40

10W-30

10W-40

Do not refuel while smoking or near open
flame or other such potential fire hazards.
Otherwise fire accident may occur.

WARNING

8. DC CIRCUIT BREAKER (See Fig. 

2

2

-

y

y

)

DC circuit breakers shut off electric current when
the current exceeds its limit or a malfunction occurs
in the connected appliance. 
Check for excessive current consumption or defects
in the appliance. After making sure everything is in
order, push the button to the " ON " position.

q

BUTTON

e

IN (ON)

w

KNOB

r

OUT (OFF)

7. DC TERMINALS (See Fig. 

2

2

-

t

t

)

DC electric power for battery charge is available. 

- Red is positive (+) terminal.
- Black is negative (-) terminal.

10. RECOIL STARTER (See Fig. 

2

2

-

u

u

)

Pull this handle to start the generator. 

q

RECOIL STARTER HANDLE

q

FUEL TANK CAP

w

FUEL FILTER SCREEN

e

TANK CAP COVER

9. GROUND TERMINAL (See Fig. 

2

2

-

i

i

)

Terminal for grounding the generator.

12. SIDE COVER (

.

.) (See Fig. 

2

2

-

!

!00

)

To access the following items for servicing, take the
applicable side cover out by removing the screw
with screwdriver or coin.

LH-side cover

---- Air cleaner etc.

RH-side cover

---- Oil level gauge, Ignition coil,

Spark plug etc.

11. FUEL TANK CAP (See Fig. 

2

2

-

o

o

)

The fuel tank cap is located behind the cover.
To open the cover, lift up with the dent portion
depressed backward as shown in the illustration.
Remove the fuel tank cap by turning
counterclockwise.

If circuit breaker continues to be activated,
discontinue use and check generator
and/or appliance for malfunction with
their respective service representatives.
Never interfere with the operation of the
circuit breaker knob or keep pushing it in
the "ON" position.

CAUTION

G1700I(CSA)̲GU1979  05.1.26  10:53 AM  ページ6

Summary of Contents for G1700I

Page 1: ...3ZZ9990147 GENERATOR カナダ MODEL ...

Page 2: ... 10 1 5 4 1 2 3 4 3 7 6 1 2 3 1 2 3 3 1 1 2 2 3 4 1 2 6 1 2 3 4 12 11 10 6 7 8 9 1 2 1 2 PILOT LAMP OVER LOAD 5 1 1 2 1 1 1 2 1 2 ON STOP RUN CHOKE OFF STOP RUN CHOKE STOP RUN CHOKE 3 4 STOP RUN CHOKE ON OFF AUTO POWER SAVE ...

Page 3: ...a Factory Service Center or Service Center authorized by MAKITA during a warranty repair alteration accident failure to use the recommended fuel and oil or not performing required maintenance services The replacement parts used for required maintenance services Consequential damages such as loss of time inconvenience loss of use of the engine or equipment etc Diagnosis and inspection charges that ...

Page 4: ...1 4877 SASKATCHEWAN SASKATOON 206A 2750 Faithful Avenue Saskatoon S7K 6M6 Tel 1 888 931 0111 or 306 931 0111 Fax 306 931 4574 MANITOBA WINNIPEG 1670 St James Street Winnipeg R3H 0L3 Tel 1 800 550 5073 or 204 694 0402 Fax 204 694 5782 ONTARIO LONDON 317 Adelaide Street S Unit 117 London N5Z 3L3 Tel 1 800 571 0899 or 519 686 3115 Fax 519 686 4347 MISSISSAUGA 6350 Tomken Road Unit 8 Mississauga L5T 1...

Page 5: ...r products certain procedures and specifications are subject to change without notice When ordering spare parts always give us the MODEL PRODUCTION NUMBER PROD No and SERIAL NUMBER SER No of your Product Please fill in the following blanks after checking the production number on your product Location of label is different depending on the product model CONTENTS 1 SAFETY PRECAUTIONS 2 2 COMPONENTS ...

Page 6: ... such a case piston seizure may occur even if the oil is above the upper level WARNING Pay attention to the wiring or extension cords from the generator to the connected device If the wire is under the generator or in contact with a vibrating part it may break and possibly cause a fire generator burnout or electric shock hazard Replace damaged or worn cords immediately WARNING Do not operate the g...

Page 7: ...tarting Do not pour water directly over the generator nor wash it with water WARNING Be extremely careful that all necessary electrical grounding procedures are followed during each and every use Failure to do so can be fatal WARNING It is absolutely essential that you know the safe and proper use of the power tool or appliance that you intend to use All operators must read understand and follow t...

Page 8: ...g the hot area Do not connect the generator to the commercial power lines Engine oil ON power and Engine Add oil Battery charging condition OFF power and Engine Alternating current Direct current Plus positive polarity Minus negative polarity OUT position of a bistable push control IN position of a bistable push control Protective earth ground Fuse Choke cold starting aid Engine start Electric sta...

Page 9: ...g plug as shown CHOKE To start the engine turn the knob to the position Choke valve is closed RUN Keep the knob in this position after the engine starts The engine can be started with the knob at this position when the engine is warm STOP To stop the engine return the knob to the position The fuel cock is closed as well Do not plug more than two appliances into the generator at a time Do not put f...

Page 10: ...W 20W 20 30 40 10W 30 10W 40 Do not refuel while smoking or near open flame or other such potential fire hazards Otherwise fire accident may occur WARNING 8 DC CIRCUIT BREAKER See Fig 2 2 y y DC circuit breakers shut off electric current when the current exceeds its limit or a malfunction occurs in the connected appliance Check for excessive current consumption or defects in the appliance After ma...

Page 11: ...her structures Only operate generator in a dry well ventilated area Keep exhaust pipe clear of foreign objects Keep generator away from open flame No smoking Keep generator on a stable and level surface Do not block generator air vents with paper or other material WARNING 5 OPERATING PROCEDURES See Fig 4 4 1 STARTING THE GENERATOR a Make sure the appliance is disconnected b Turn engine switch to C...

Page 12: ...e pilot lamp is turned off during the proper operation 1 AC APPLICATION See Fig 4 4 r r a Make sure the pilot lamp is turned on b Turn off the switch es of the electrical appliance s before connecting to the generator c Insert the plug s of the electrical appliance s into the receptacle See Fig 4 r Check the amperage of the receptacles used referring to TABLE 1 and be sure not to take a current ex...

Page 13: ...When charging a large capacity battery or totally discharged battery excessive current may force the DC breaker to turn off In such cases use a battery charger to charge a large battery with AC output Battery defects may cause the DC breaker to turn off Check the battery before replacing the DC breaker 3 STOPPING THE GENERATOR a Turn off the power switch of the electric equipment and unplug the co...

Page 14: ...rvice center with questions regarding power surge of certain appliances or power tools 6 WATTAGE INFORMATION To determine the total wattage required to run a particular electrical appliance or tool multiply the voltage figure of the appliance tool by the amperage amps figure of same The voltage and amperage amps information can be found on a name plate which is normally attached to electrical appl...

Page 15: ... spark arrester will be very hot Allow the muffler to cool before cleaning the spark arrester How to remove the spark arrester 1 Remove the flange bolts from the muffler cover and remove the muffler cover 2 Remove the special screw from the spark arrester and remove the spark arrester from the muffler SPARK ARRESTER SCREEN SCREW MUFFLER Clean the spark arrester screen Use a brush to remove carbon ...

Page 16: ...LSO NECESSARY FOR THE USER OF THIS GENERATOR TO CONDUCT THE MAINTENANCE AND ADJUSTMENTS ON THE EMISSION RELATED PARTS LISTED BELOW TO KEEP THE EMISSION CONTROL SYSTEM EFFECTIVE The emission control system consists of the following parts The maintenance schedule indicated in the table is based on the normal generator operation Should the generator be operated in extremely dusty condition or in heav...

Page 17: ...ry 1000 hours Every 500 hours Every 200 hours Monthly Every 50 hours Weekly Every 8 hours Daily Clean generator and check bolt and nuts Daily Daily Yearly Daily Daily Check and refill engine oil Change engine oil Note1 Clean spark plug Clean air cleaner Replace air cleaner element Clean fuel filter Remove carbon from cylinder head Note 2 Check and adjust valve clearance Note 2 Clean and adjust car...

Page 18: ...ll the engine with oil until it reaches the upper level on the oil filler cap Use fresh and high quality lubricating oil to the specified level as directed on page 6 If contaminated or deteriorated oil is used or the quantity of the engine oil is not sufficient the engine damage will result and its life will be greatly shortened Make sure the engine is stopped before starting any maintenance servi...

Page 19: ...on Store generator in a well ventilated low humidity area 11 TRANSPORTING When transporting the generator make sure that the fuel gasoline should be drained from the tank a Turn the engine switch to the STOP position b Drain the fuel from the tank To prevent fuel spillage due to the vibration and impact never transport the generator with the fuel gasoline filled in the tank Secure the tank cap tho...

Page 20: ... connected appliance and unplug Remove spark plug and clean electrode If the engine oil level is low add the oil to the upper level line on the oil gauge If loose push spark plug cap back into place When Engine Fails to Start When No Electricity Is Generated at Receptacle Check if the DC circuit breaker is turned OFF Check if the Overload Lamp is turned ON Red and or AC breaker is turned OFF Check...

Page 21: ... 0 106 Type Forced air cooled 4 cycle single cylinder OHV type gasoline engine Displacement mL cu in 85 8 5 23 Length mm in Width mm in High mm in 480 19 3 295 11 6 445 17 5 Dry weight kg lb 20 5 45 2 Fuel tank capacity L U S gal 3 5 0 92 Valve Clearance Intake Exhaust mm in 0 1 0 03 0 0039 0 0012 Note Adjust the valve clearance while the engine is cold Rated continuous operation Approx hours 3 5 ...

Page 22: ...low W Blk White Black Pur Purple ENGINE SWITCH Y Gry Org Y R Blu Gry R W Grn Y MAIN COIL W Blk W W R Grn Y AUTO POWER SAVE SWITCH AC CIRCUIT BRAKER AC RECEPTACLE EARTH PLATE Grn Y DC COIL Pin Gry W Blk R Brn Grn Y Brn W R Grn Blu Pur Gry Blk Gry Org Brn W W R Blu INVERTER ENGINE CONTROL UNIT IGNITION COIL PICKUP COIL DC CIRCUIT BRAKER EARTH GROUND TERMINAL OIL LEVEL SENSOR STEP MOTOR DC OUTPUT TER...

Page 23: ......

Page 24: ...ISSUE EMD GU1979 Makita Corporation 3 11 8 Sumiyoshi cho Anjo Aichi 446 8502 Japan PRINTED IN JAPAN December 2004 CE ...

Reviews: