10
−
GROUNDING THE
GENERATOR
■
To ground the generator to the earth,
connect the grounding lug of the gen-
erator to the grounding spike driven
into the earth or to the conductor
which has been already grounded to
the earth.
■
If such grounding conductor or
grounding electrode is unavailable,
connect the grounding lug of the gen-
erator to the grounding terminal of the
using electric tool or appliance.
GROUNDING SPIKE
EARTH TERMINAL