11. TROUBLESHOOTING
−
32
−
When generator engine fails to start after several attempts, or if no electricity is
available at the output socket, check the following chart. If your generator still fails
to start or generate electricity, contact your nearest
Makita factory or authorized
service center for further information or corrective procedures.
When Engine Fails to Start :
When No Electricity Is Generated at Receptacle :
Check if choke lever is in its proper
position.
Check if fuel cock is open.
Check fuel level.
Check to make sure generator is not
connected to an appliance.
Check spark plug for loose spark plug
cap.
Check spark plug for contamination.
Check if engine switch is in OFF.
Set the choke lever to "CLOSE" posi-
tion.
If closed, open fuel cock.
If empty, refill fuel tank making sure not
to overfill.
If connected, turn off the power switch
on the connected appliance and unplug.
If loose, push spark plug cap back into
place.
Remove spark plug and clean electrode.
Turn engine switch to ON.
Check to make sure no-fuse breaker is
in the "ON" position.
Check AC and DC terminals for loose
connection.
Check to see if engine starting was
attempted with appliances already con-
nected to generator.
After making sure that the total wattage
of the electrical appliance is within per-
missible limits and there are no defects
in the appliance, turn the no-fuse break-
er to the "ON" position.
If breakers continue to actuate, consult
your nearest servicing dealer.
Secure connection if necessary.
Turn off switch on the appliance, and
disconnect cable from receptacle.
Reconnect after generator has been
started properly.
G28R-G61R 米国取説GU2016 05.1.26 11:15 AM ページ32