9 ENGLISH
Work mode: disc sanding with normal side grip
Vibration emission (a
h, DS
) : 3.4 m/s
2
Uncertainty (K) : 1.5 m/s
2
Work mode: disc sanding with anti vibration side grip
Vibration emission (a
h, DS
) : 3.9 m/s
2
Uncertainty (K) : 1.5 m/s
2
Model GA9070
Work mode: surface grinding with normal side grip
Vibration emission (a
h, AG
) : 4.9 m/s
2
Uncertainty (K) : 1.5 m/s
2
Work mode: surface grinding with anti vibration side grip
Vibration emission (a
h, AG
) : 4.8 m/s
2
Uncertainty (K) : 1.5 m/s
2
Work mode: disc sanding with normal side grip
Vibration emission (a
h, DS
) : 2.5 m/s
2
or less
Uncertainty (K) : 1.5 m/s
2
Work mode: disc sanding with anti vibration side grip
Vibration emission (a
h, DS
) : 2.6 m/s
2
Uncertainty (K) : 1.5 m/s
2
Model GA9071
Work mode: surface grinding with normal side grip
Vibration emission (a
h, AG
) : 5.1 m/s
2
Uncertainty (K) : 1.5 m/s
2
Work mode: surface grinding with anti vibration side grip
Vibration emission (a
h, AG
) : 4.9 m/s
2
Uncertainty (K) : 1.5 m/s
2
Work mode: disc sanding with normal side grip
Vibration emission (a
h, DS
) : 3.1 m/s
2
Uncertainty (K) : 1.5 m/s
2
Work mode: disc sanding with anti vibration side grip
Vibration emission (a
h, DS
) : 3.1 m/s
2
Uncertainty (K) : 1.5 m/s
2
NOTE:
The declared vibration total value(s) has been
measured in accordance with a standard test method
and may be used for comparing one tool with another.
NOTE:
The declared vibration total value(s) may also
be used in a preliminary assessment of exposure.
WARNING:
The vibration emission during
actual use of the power tool can differ from the
declared value(s) depending on the ways in which
the tool is used especially what kind of workpiece
is processed.
WARNING:
Be sure to identify safety mea-
sures to protect the operator that are based on an
estimation of exposure in the actual conditions of
use (taking account of all parts of the operating
cycle such as the times when the tool is switched
off and when it is running idle in addition to the
trigger time).
WARNING:
The declared vibration emission
value is used for main applications of the power tool.
However if the power tool is used for other applica
-
tions, the vibration emission value may be different.
EC Declaration of Conformity
For European countries only
The EC declaration of conformity is included as Annex A
to this instruction manual.
SAFETY WARNINGS
General power tool safety warnings
WARNING:
Read all safety warnings, instruc-
tions, illustrations and specifications provided
with this power tool.
Failure to follow all instructions
listed below may result in electric shock, fire and/or
serious injury.
Save all warnings and instruc-
tions for future reference.
The term "power tool" in the warnings refers to your
mains-operated (corded) power tool or battery-operated
(cordless) power tool.
Grinder safety warnings
Safety Warnings Common for Grinding, Sanding,
Wire Brushing, or Abrasive Cutting-Off Operations:
1.
This power tool is intended to function as a
grinder, sander, wire brush or cut-off tool. Read
all safety warnings, instructions, illustrations
and specifications provided with this power tool.
Failure to follow all instructions listed below may
result in electric shock, fire and/or serious injury.
2.
Operations such as polishing are not recom-
mended to be performed with this power tool.
Operations for which the power tool was not designed
may create a hazard and cause personal injury.
3.
Do not use accessories which are not specifi
-
cally designed and recommended by the tool
manufacturer.
Just because the accessory can
be attached to your power tool, it does not assure
safe operation.
4.
The rated speed of the accessory must be at
least equal to the maximum speed marked on
the power tool.
Accessories running faster than
their rated speed can break and fly apart.
5.
The outside diameter and the thickness of your
accessory must be within the capacity rating
of your power tool.
Incorrectly sized accessories
cannot be adequately guarded or controlled.
6.
Threaded mounting of accessories must match
the grinder spindle thread. For accessories
mounted by flanges, the arbour hole of the
accessory must fit the locating diameter of the
flange.
Accessories that do not match the mounting
hardware of the power tool will run out of balance,
vibrate excessively and may cause loss of control.
7.
Do not use a damaged accessory. Before each
use inspect the accessory such as abrasive
wheels for chips and cracks, backing pad for
cracks, tear or excess wear, wire brush for
loose or cracked wires. If power tool or acces-
sory is dropped, inspect for damage or install
an undamaged accessory. After inspecting and
installing an accessory, position yourself and
bystanders away from the plane of the rotating
accessory and run the power tool at maximum
no-load speed for one minute.
Damaged acces-
sories will normally break apart during this test
time.
Summary of Contents for GA7071
Page 2: ...1 Fig 1 1 2 3 Fig 2 1 2 3 Fig 3 B C 2 1 A Fig 4 B C 2 1 A Fig 5 1 Fig 6 Fig 7 1 2 3 Fig 8 2 ...
Page 5: ...1 Fig 24 1 Fig 25 1 2 4 5 6 3 Fig 26 Fig 27 1 2 Fig 28 Fig 29 Fig 30 Fig 31 5 ...
Page 6: ...Fig 32 Fig 33 1 Fig 34 1 2 Fig 35 6 ...
Page 7: ...1 2 3 5 4 6 3 3 8 5 9 7 8 5 6 11 10 5 12 13 14 20 18 19 5 17 21 3 22 5 2 2 15 16 Fig 36 7 ...
Page 118: ...118 ...
Page 119: ...119 ...