W
iring diagram
Lead wire (purple) between reversible switch and brush holder
has to be passed trough the space between rib and inner wall.
Rib
Lead wire (black) between reversible
switch and main switch (ON - OFF)
has to be passed through back of the rib.
Lead wires (black and white)
of field has to be passed under
boss, and has to be guided
through guide hole.
Boss
Guide hole
Lead wires have to be
set in the lead holder.
Choke coil
Noise
suppressor
Receptacles have to
be faced to the motor
housing side as
illustrated in Fig.17A.
Fig.17A.
Fig.17
Motor housing
Receptacle
Brush holder
Receptacles have to be faced to the
bottom side of motor housing as illustrated
in Fig 17A.
If they would be faced to handle cover side,
handle cover can not be assembled to
motor housing, in case may be.