C

ircuit diagram

P 14  / 17 

White

Yellow

DC Motor

Red point mark

Fig. D-1

Controller

Line filter (if used)

Line filter (if used)

Controller unit

Terminal

Flag receptacle

with lock

(#250, t=0.8mm)

Flag receptacle with lock (#250, t=0.8mm)

Flag receptacle

without lock

(#187, t=0.5mm)

Straight receptacle

with lock

(#250, t=0.8mm)

Switch

Color index of lead wires' sheath

Black
Red

COM

NO

T

16 AWG*

16 AWG*

16 AWG*

16 AWG*

Flag receptacle

with lock

(#187, t=0.8mm)

16 AWG*

22 AWG*

* AWG: American Wire Gauge

Switch circuit

COM

NO

Summary of Contents for HS301D

Page 1: ...1 500 0 45 17 22 44 25 5 1 16 5 5 8 Cutting capacity mm at 0 at 45 Weight according to EPTA Procedure 01 2003 4 kg lbs 1 6 3 5 2 1 8 3 9 3 Yes Soft grip Yes Yes on the battery Blower function Battery...

Page 2: ...ndle Helical gear 28 removing Ball bearing 604ZZ disassembling assembling Bearing retainer 14 23 press fitting Helical gear 47 and Helical gear 28 2 LUBRICATION Fig 1 Item No Description Handle set R...

Page 3: ...rque N m Q ty 1 2 1 12 16 2 4 3 5 1 3 1 8 Use for 34 36 45 54 55 56 57 53 46 47 48 Screwdriver 49 DISASSEMBLING 32 1 Unscrew M5x10 Thumb screw 45 Remove Spring washer 5 46 and Flat washer 5 47 2 Unscr...

Page 4: ...Assemble Compression spring 4 14 to Lock off lever 9 Assemble Compression spring 4 8 to Switch lever 15 Note Compression spring 4 14 and Compression spring 4 8 are the same 2 Disassemble Lock off lev...

Page 5: ...pring 4 38 from Safety cover 39 3 DISASSEMBLY ASSEMBLY Fig 7 Fig 8 Fig 6 39 38 39 40 41 1R003 1R212 38 1 Set the hook of Tension spring 4 38 to Safety cover 39 as drawn 2 After setting Safety cover 39...

Page 6: ...te Motor housing set 1 3 and Gear housing complete 23 Remove Duct 19 by unscrewing one 4x18 Tapping screw 18 18 19 3 Striking Handle set R 17 remove Helical gear 47 26 section consisted of Ball bearin...

Page 7: ...ng them into the gap between Helical gear 47 26 and Ball bearing 604ZZ 25 Set them on Arbor press Applying 1R278 to Helical gear 9B 28 press with Arbor press 5 Disassemble Ball bearing 606ZZ 27 from H...

Page 8: ...to Gear housing complete 23 1R027 27 28 26 1R028 1 Press fit Ball bearing 606ZZ 27 to Helical gear 9B 28 with 1R027 2 Press fit Helical gear 47 26 to Helical gear 9B 28 with 1R028 25 23 3 Press fit Ba...

Page 9: ...ing two M5x16 Countersunk head screw 36 4 Remove O ring 26 33 Note M5x16 Counter sunk head screw is adhesive Use Cordless impact driver for removing 5 Put Bearing box 34 on 1R164 Applying 1R283 to Spi...

Page 10: ...26 34 Bearing box 36 M5x16 Counter sunk head screw 37 Thickness ring 7 Protecting Bearing box 34 with 1R041 set it as drawn 8 Remove Bearing retainer 35 with 1R361 by turning counterclockwise 9 Pass...

Page 11: ...by pressing 1R028 with Arbor press 5 Support Bearing box 34 with 1R164 Using 1R028 press fit the entire of Spindle section to Bearing box 34 1 Put Ball bearing 6900DDW 32 into Bearing box 34 2 Put Bea...

Page 12: ...rget to mount O ring 26 33 to Bearing box 34 at the illustrated portion 7 Do not forget to mount Thickness ring 37 to Bearing box 34 at the illustrated portion 8 Tighten Bearing box 34 with two M5x12...

Page 13: ...Fig 30 2 6 1 Unscrewing six 4x18 Tapping screws 6 disassemble Handle set L 17 2 Unscrewing three 4x30 Tapping screws 2 disassemble Motor housing set 1 3 1 Unscrewing four 4x18 Tapping screws 4 disasse...

Page 14: ...Flag receptacle with lock 250 t 0 8mm Flag receptacle with lock 250 t 0 8mm Flag receptacle without lock 187 t 0 5mm Straight receptacle with lock 250 t 0 8mm Switch Color index of lead wires sheath...

Page 15: ...ted Fig D 2 Fig D 3 Rib A Lead wire holder 1 1 20 Put lead wires to this lead wire holder Put Line filter between Rib A and Rib B if it is used Put Lead wires to this groove Line filter Rib B Wiring t...

Page 16: ...inal The following lead wires has to be put in this portion Lead wire black for connecting to DC Motor Lead wire black for connecting to Terminal Fig D 4 10 Put the following lead wires between Boss A...

Page 17: ...dle set R 17 side 11 Flag receptacle Terminal Wiring in Handle set R Lead wire white 11 tape Do not put any lead wires on these ribs Do not put any lead wires on this rib Do not put any lead wires on...