W
iring diagram
P 15 / 17
Red point mark
Flag receptacle
Connect Flag receptacles to DC Motor (20)
as follows.
* Connect receptacle with red lead wire
to the Motor terminal designated with
red point mark.
* Connect terminals so that the lead wires
are guided to Motor housing L (1) side
as illustrated.
Fig. D-2
Fig. D-3
Rib A
Lead wire
holder
(1)
(1)
(20)
Put lead wires to this
lead wire holder.
Put Line filter between
Rib A and Rib B if it is used.
Put Lead wires to
this groove.
Line filter
Rib B
Wiring to DC Motor
Wiring in Motor housing
Put DC Motor to Motor housing L (1) so that
the lead wires can be easily guided to the
bottom of Motor housing L.
Put lead wires deeply to
the space between the
following ribs.
* Rib for Ball bearing set
and
* Rib of the rear side of
Motor housing L
Red mark