4 ENGLISH
ENGLISH (Original instructions)
SPECIFICATIONS
Model:
M8701
Drilling capacities
Concrete
26 mm
Core bit
68 mm
Diamond core bit (dry type)
80 mm
Steel
13 mm
Wood
32 mm
No load speed
0 - 1,200 min
-1
Blows per minute
0 - 4,500 min
-1
Overall length
362 mm
Net weight
2.7 kg
Safety class
/II
•
Due to our continuing program of research and development, the specifications herein are subject to change
without notice.
•
Specifications may differ from country to country.
•
Weight according to EPTA-Procedure 01/2003
Intended use
The tool is intended for hammer drilling and drilling in
brick, concrete and stone as well as for chiselling work.
It is also suitable for drilling without impact in wood,
metal, ceramic and plastic.
Power supply
The tool should be connected only to a power supply of
the same voltage as indicated on the nameplate, and
can only be operated on single-phase AC supply. They
are double-insulated and can, therefore, also be used
from sockets without earth wire.
Noise
The typical A-weighted noise level determined accord
-
ing to EN60745:
Sound pressure level (L
pA
) : 90 dB(A)
Sound power level (L
WA
) : 101 dB (A)
Uncertainty (K) : 3 dB(A)
WARNING:
Wear ear protection.
Vibration
The vibration total value (tri-axial vector sum) deter
-
mined according to EN60745:
Work mode: hammer drilling into concrete
Vibration emission (a
h, HD
): 16.5 m/s
2
Uncertainty (K) : 1.5 m/s
2
Work mode: chiselling function with side grip
Vibration emission (a
h, Cheq
): 9.0 m/s
2
Uncertainty (K) : 1.5 m/s
2
Work mode: drilling into metal
Vibration emission (a
h,D
) : 2.5 m/s
2
or less
Uncertainty (K) : 1.5 m/s
2
NOTE:
The declared vibration emission value has
been measured in accordance with the standard test
method and may be used for comparing one tool with
another.
NOTE:
The declared vibration emission value
may also be used in a preliminary assessment of
exposure.
WARNING:
The vibration emission during actual
use of the power tool can differ from the declared
emission value depending on the ways in which the
tool is used.
WARNING:
Be sure to identify safety measures
to protect the operator that are based on an estima-
tion of exposure in the actual conditions of use (taking
account of all parts of the operating cycle such as
the times when the tool is switched off and when it is
running idle in addition to the trigger time).
EC Declaration of Conformity
For European countries only
The EC declaration of conformity is included as Annex A
to this instruction manual.
SAFETY WARNINGS
General power tool safety warnings
WARNING:
Read all safety warnings and
all instructions.
Failure to follow the warnings and
instructions may result in electric shock, fire and/or
serious injury.