background image

P  

 

R

epair

It is not required to lubricate the machine, because of no gear mechanism to be lubricated.

[3] DISASSEMBLY/ASSEMBLY

[3] -1. Armature fan

[1] NECESSARY REPAIRING TOOLS

CAUTION: Repair the machine in accordance with “Instruction  manual” or “Safety instructions”.

Code No.

Description

Use for

1R269

Bearing extractor

removing Ball bearing from Armature

[2] LUBRICATION

DISASSEMBLING

(1) Disassemble Armature as drawn in 

Fig. 1

.

1. Turn Nozzle counterclockwise 

    viewing from exhaust hole side

    until it stops. And then pull it off.

2. Separate Housing R together with

    Inner housing by unscrewing 

    eight 4x18 Tapping screws.

3. Remove Brush holders 

    from Housing L.

4. Remove Motor section from

    Housing R.

Housing R

Inner

housing

M5x8

Hex nut

Flat washer 5

5. Remove M5 Hex nut for Fan 100 by turning it 

counterclockwise

    with wrench, and remove Flat washer 5.

    Fan 100 and Flat washer 8 can be now removed.

Flat washer 8

Brush holders

Armature 

Nozzle.

Fig. 1

Fan 100

Summary of Contents for maktec MT401

Page 1: ...zzle 2 with Nozzle 3 with Nozzle assembly Joint 8 500 16 000 Double insulation 1 2 2 9 42 4 102 4 2 0 6 6 1 5 3 4 37 87 121 4 285 4 MT401 Blower CONCEPT AND MAIN APPLICATIONS Specification Standard equipment Note The standard equipment for the tool shown may vary by country L H W Weight according to EPTA Procedure 01 2003 3 kg lbs Flexible hose Long nozzle Optional accessories PRODUCT P 1 Model MT...

Page 2: ...EMBLING 1 Disassemble Armature as drawn in Fig 1 1 Turn Nozzle counterclockwise viewing from exhaust hole side until it stops And then pull it off 2 Separate Housing R together with Inner housing by unscrewing eight 4x18 Tapping screws 3 Remove Brush holders from Housing L 4 Remove Motor section from Housing R Housing R Inner housing M5x8 Hex nut Flat washer 5 5 Remove M5 Hex nut for Fan 100 by tu...

Page 3: ...rive end Ball bearing 608ZZ commutator end Ball bearing 627ZZ Ball bearing 627ZZ 1R269 Fig 2 3 DISASSEMBLY ASSEMBLY 3 1 Armature fan cont Noise suppressor is not used for some countries 1 2 3 4 Circuit diagram White Blue Brown Grounding terminal Grounding terminal of Noise suppressor is not used for some countries Line filter is not used for some countries Switch Field Line filter Power supply cor...

Page 4: ...g terminal of Noise suppressor is not used for some countries Pass Field lead wires black white through Line filter as drawn below and put them to this position Line filter Line filter Field lead wires Fig D 2 Noise suppressor is not used for some countries Put Lead wires connected to Controller in this Lead wire holder Connect Terminal on Lead wire to Brush holder from the opposite side of Field ...