background image

 

P  

7

8

C

ircuit diagram

W

iring diagram

Fig. D-1 

Fig. D-2 

White

Noise 

suppressor

Switch

viewed from Commutator side

Brush

holder B

Brush

holder A 

Line filter

Power  supply cord

Color index of lead wires' sheath

Black

Blue

Brown

Field

connected to

Switch

Field

Motor housing

complete

Wiring of Field lead wires

connected to

Switch

Slit

Field lead wires

Lead wire

holder

1. Mount Filed to Motor housing complete as shown below.

Lead wire (

white

 or 

blue

) of Power supply

cord connected to P2 terminal

Lead wire (

black

 or 

brown

) of Power supply

cord connected to P1 terminal

Note:

 Noise suppressor and Line filter are not

 

used for some countries.

2. Route Field lead wires through the slit

  and Lead wire holder as shown below.

Summary of Contents for UB1102

Page 1: ...lower Weight according to EPTA Procedure 01 2003 2 kg lbs Dust bag assembly Nozzle assembly Long nozzle assembly Flexible hose set Anchor nozzle set for vacuum function only Bending long nozzle set PR...

Page 2: ...ng Field Assemble Switch by reversing the disassembly procedure Refer to Fig 1 Note When mounting Handle cover be careful of the following Switch and Lead wire are not pinched with Handle cover Refer...

Page 3: ...mall screwdriver until it stops Refer to the drawing on the top right in Fig 2 Fig 2 ASSEMBLING Fan cover Fan 110 M5 8 Hex nut Flat washer 5 Flat washer 8 1 Remove Nozzle Nozzle 3 Unscrew five 4x18 Ta...

Page 4: ...2 Disassemble Fan section as drawn in Fig 2 3 Disassemble Armature as drawn in Fig 4 Fig 3 Fig 4 Flat washer 8 Armature Fan housing complete 1 Unscrew four 4x35 Tapping screws and disassemble Fan hou...

Page 5: ...rminal Field Field 1 Unscrew four 4x18 Tapping screws and remove Handle cover 3 Disconnect Ring terminals from Brush holders with a Slotted screwdriver Note Tapping the edge of Motor housing with a pl...

Page 6: ...l 1R370 Fig 7 1R063 Field 3 Connect field lead wires to Switch and mount Handle cover to Motor housing with four 4x18 Tapping screws Refer to the drawings on the top left and right in Fig 5 4 Insert A...

Page 7: ...Motor housing complete Wiring of Field lead wires connected to Switch Slit Field lead wires Lead wire holder 1 Mount Filed to Motor housing complete as shown below Lead wire white or blue of Power sup...

Page 8: ...Line filter if used Set Line filter with Field lead wires between Lead wire holders 1 Pass Field lead wires through Line filter and wind them one turn and pass them again as shown below 2 Winded Filed...

Reviews: