Quick Installation Guide For Petroleum Sites with Mako Performing MNSP Function v2.1.1
Type 3: New Install with Outside EMV with Wayne dispensers
1)
LAN 1 (Card Net) should be cabled to slot A on the Commander or the Payment Network port on
the Commander 16/RubyCi.
2)
LAN2 (VFI POS) connects to the Mako-supplied switch. The Verifone POS and Verifone Zone port
(N on the Commander and Ethernet Symbol on Commander 16/RubyCi) will connect to the Mako-
supplied switch.
3)
LAN3 (Store) needs to be cabled to the customer back-office switch if available.
4)
LAN4 (Outside EMV) should be connected to the Mako-supplied eight port managed switch.
Network layout with Wayne Ovation dispensers:
LAN 1
LAN 2
LAN 3
M A KO 6 0 0 0 S E R I E S
BACK OFFICE
PC
VERIFONE
COMMANDER
LAN 4
MEDIA GATEWAY
(IF PRESENT )
ANTHEM EDGE
(IF PRESENT )
MAKO
LAN 4
UNMANAGED
SWITCH
PINPAD
PINPAD
POS
WAYNE CONNECT
IP-485/S
WAYNE CONNECT
IP-485/D
FUELING PUMP 1
FUELING PUMP 2