background image

CAUTION!

PLEASE READ CAREFULLY BEFORE

OPERATING THE DEVICE!

This device must only be repaired by authorized service, the 

warranties of devices unpacked by the user or third parties are 

void. 

The device and coils should not be stored in extreme cold or hot 

environments for a long time. Suitable range of temperature is 0 

to 45C.

The device should not be installed or operated without reading 

the user manual.  

Device and the accessories should not be submerged into water 

or stored in excess moisture, except for the coil. 

The device should be protected against the impact that may 

occur in transport. 

You have to follow local legislation and regulations while using the 

device. This device must not be used in military zones, residential 

areas and ruins. Related authorities must be informed about the 

historical and cultural findings encountered in searches.

1-

2-

3-

4-

5-

Summary of Contents for CF77

Page 1: ...www makrodetector com USER GUIDE...

Page 2: ...evice should not be installed or operated without reading the user manual Device and the accessories should not be submerged into water or stored in excess moisture except for the coil The device shou...

Page 3: ...and accessories System control unit Battery Assembly Usage Settings Ground setting Search and metal detection Troubleshooting and maintenance Technical specifications 1 2 3 4 5 7 9 10 11 13 14 ThankY...

Page 4: ...l separati on make it suitable in waste metal rich areas C23 Coil and Cover Pro Package 23 cm 9 Water resistant Double D coil designed for users requiring deeper search It provides more advantage comp...

Page 5: ...2 PARTS and ACCESSORIES S Tube System Unit and Armrest Extension Tube Coil Connection Parts System Unit Connection Parts Headphone Battery Box Cover Battery Box Carry Bag Pro Package...

Page 6: ...3 SYSTEM CONTROL UNIT 6 2 3 4 1 5 7 8 On Off and Mode Selection switch Sensitivity Ground Setting Iron Audio Volume 1 2 3 4 5 Coil Input Battery Input Headphone Output 6 7 8...

Page 7: ...mA batteries provide longer use compared to low Ma batteries Fully charged alkaline batteries last maximum 30 hours Other type and brand of batteries in the market may differ in operating life Your d...

Page 8: ...button on the upper tube mount it on the S Tube and tighten its sleeve by inserting the metal button in the socket 3 Insert the seals in the sockets at the end of the extension tube Insert the extens...

Page 9: ...nder the system box and fasten by tightening 7 4 By winding coil wire as seen in the picture fasten and tighten the connector at the end of the wire in the coil input under the system box In case you...

Page 10: ...7 USAGE Ensure that coil always remains parallel to the ground during searches RIGHT Failing to keep the coil in a position parallel to the ground may cause faulty results WRONG WRONG RIGHT...

Page 11: ...8 USAGE CORRECT HOLD WRONG HOLD...

Page 12: ...ric lines in the environment Sensitivity setting is also the depth setting When sensitivity is set to be at maximum level depth will increase to maximum too SENSITIVITY This is a part providing ferrou...

Page 13: ...her nn ferrous metals In these cases ground setting should be repeated by gradually decreasing sensitivity In case ground setting cannot be achieved and the device produces deep sounds when iron sound...

Page 14: ...et it does not detect the metal if you hold it steady on the metal Target Target Device provides metals with single sound in GENERAL MODE and 3 different sounds in MODE 1 and 2 2 similar sounds for no...

Page 15: ...en the target is detected dig the surface by 3 5 cm and check the signal again If no signal is received the target is in the dig part If the target is still in the ground cut the section which you thi...

Page 16: ...purchased does not require extensive maintenance as it is manufac tured with high quality material Following are the recommendations in order to get the best performance and be able to operate the dev...

Page 17: ...cm 16 x 18 850 gr 1 9 lb 30 oz 127 152 cm 50 60 1 090 gr 2 4 lb 38 5 oz C23 Coil Pro Package C28 Coil Standard Package System Unit and Handset C45 Coil Pro Package Total weight including standard C23...

Page 18: ...www makrodetector com info makrodetector com MAKRO DETECTOR DEALER...

Reviews: