15
6
. FULL AUTOMATIC PELLET BOILER CONTROL
PANEL
On – Off – Reset
This is on off button of the boiler.
It is used to reset when the boiler breaks down.
Touch the button for 2 seconds to switch on, off and reset.
Fuel Load
This button is used for manuel preloading by only authorized services during initial operation
(End users must not do preloading)
Temperature
Setting
To increase or decrease the boiler temperature, press
the button once and adjust settings with up and down buttons.
Fan Setting
To adjust the fan speed, press the button once and adjust with up and down buttons.
Fuel Loading
Time (sec)
If the factory settings do not suffice, press the button once to change the fuel loading values
and adjust with up and down buttons.
Fuel Waiting
Time (sec)
If the factory settings do not suffice, press the button once to change the fuel waiting values
and adjust with up and down buttons.
Up Button
Enter the menu that will be readjusted and use this button to increase its value
Down Button
Enter the menu that will be readjusted and use this button to reduce the value.
Alarm Off
The boiler makes a warning sound when it is out of order.
Button must be pushed once to turn off the sound.
(Use the reset button to remove the boiler
from break down mode)
LCD Screen
An LCD screen that allows to monitor the boiler's running equipment and set values.
ERROR CODES
H1
No Fuel
H2
Fuel Congestion
H3
Boiler Sensor Breakdown
H4
Boiler is Overheated
H5
No Burning
H6
Overheating on Fuel Pipe
H7
Ignition Fault
H8
Chimney Sensor Fault
H9
Overheating on Chimney
H10
Fan Breakdown
H11
Overhating of Boiler Water
IMPORTANT!!!
Summary of Contents for 25MKP
Page 1: ...1...
Page 7: ...7 3 APPEARANCE OF THE BOILER AND EXTERNAL DIMENSIONS...
Page 11: ...11 4 2 BOILER INSTALLATION MOUNTING SCHEMA 1 1...
Page 16: ...16 When no setting is done the value shown at the screen is the boiler water temperature...
Page 19: ...19 USING SETTING RECOMMENDED BY THE FACTORY FAN LEVEL 3 LOADING 9 sec WAITING 29 sec...
Page 28: ...28...