5. TECHICAL SPECIFICATION

                                                                                         

TECHNICAL SPECIFICATION

Boiler Type

18 MKK 25 MKK 40 

MKK

60 
MKK

80 MKK 100 MKK 150 MKK 200 MKK 300 MKK

400 MKK

Capacity(kcal/h)

18.00

0

25.00

0

40.000 60.000 80.000 100.000 150.000 200.000 300.000

400.000

Heating  
Power(kW)

21

29

4
6

6
9

93

116

174

232

348

465

Weight(kg)

232

256

290

345

400

500

800

1050

1750

2208

Working 

Pressure(bar)

3

3

3

3

3

3

3

3

3

3

Test Pressure(bar)

  4,5

4,5

4,5

4,5

4,5

4,5

4,5

4,5

4,5

4,5

H(mm)

1130

1280

1375

1510

1620

1660

1780

1795

1625

1625

h(mm)

155

155

155

155

155

155

155

155

155

155

L(mm)

570

570

570

660

660

800

800

800

1540

1540

W(mm)

670

670

825

825

825

950

1215

1620

1750

2130

w1

180

180

250

250

250

250

250

290

220

220

w2

250

250

250

250

250

250

310

310

     310

310

ø 

D

130

130

160

160

160

180

250

250

350

350

Circulation 
Flow /Return 

1"

1"

1 1/4" 1 1/2" 1 1/2"

2"

DN65

DN65

DN100

DN100

Safety Flow

1"

1"

1"

1 1/4" 1 1/4"

1 1/4"

1/2"

1 1/2"

1 1/2"

2"

Safety Return

   1"

   1"

 1"

   1 1/4"    1 1/4"     1 1/4"     1 1/4"

1 1/4"

1 1/4"

1 1/2"

Filling-

Pouring(mm)

1/2"

1/2"

1/2"

1/2"

1/2"

1/2"

1/2"

1/2"

3/4"

3/4"

Boiler 

Adjustment
Range ( 

°

C)

35/90 35/90 35/90 35/90 35/90

35/90

35/90

35/90

35/90

35/90

Boiler Water 

Volume (lt)

32

      46

8

1

     117      174             187       380

      586

        1200

      1600

Open expansion 
(lt)

45

60

100

150

200

250

375

500

750

1000

Voltage(V/Hz)

230/50 230/50 230/50 230/50 230/50

230/50 230/50

230/50

230/50

230/50

Power (W)

160

160

188       95

     95

     95

    225

    225

    605

     605

Electric Isolation 
Level

14A

14A

14A

14A

14A

14A

14A

14A

14A

14A

Summary of Contents for MKK Series

Page 1: ......

Page 2: ...FLOOD 9 BOILER INSTALLATION SCHEMA 10 4 2 AIR CONNECTION 10 4 3 CHIMNEY 11 CHIMNEY CONNECTION SCHEMA 12 FEATURES OF THE FUEL 13 5 TECHNICAL FUTURES 14 6 CONTROL PANEL 15 7 FIRST OPERATION AND USE 17...

Page 3: ...ictly forbidden Please do not operate the boiler without water Do not feed cold water to hot boiler If for any reason the boiler temprature is over 90 degrees do not attempt to feed cold water to the...

Page 4: ...after a certain period The chimney temprature drops enabling a higher efficency The pump cable is extended outside the boilers body for connection The moving grills are designed for easy demounting w...

Page 5: ...3 SECTIONS OF THE BOILER...

Page 6: ...periodic cleaning this lid is opened to enable cleaning of the smoke pipes with boiler brush 3 Loading lid The loading of fuel to boiler is done from this lid 4 Disposal lid This is the lid that enabl...

Page 7: ...supply fresh air to the installation site air ducts is a necessity to avoid the formation of poisonous gases The boiler must be installed in a secure location unaffected by weather conditions This wi...

Page 8: ...water must be provided by natural circulation The diameter of the pipe to be used at by pass line should be the same diameter size with the pipe used in installation at minimum As an extra security m...

Page 9: ...al h 40 lt 25 MKK 25 000 kcal h 50 lt 40 MKK 40 000 kcal h 75 lt 60 MKK 60 000 kcal h 100 lt 80 MKK 80 000 kcal h 200 lt 100 MKK 100 000 kcal h 250 lt 150 MKK 150 000 kcal h 300 lt 200 MKK 200 000 kca...

Page 10: ...al length must not be shorter than 60 cm and longer than 2 meters and pipe must be connected to the chimney with minimum 10 degree of angle We suggest not to use enamel stove pipes as it creates tar i...

Page 11: ...ilding if the chimney must pass from outside the isolation must be done properly The chimney must be frequently cleaned in order to avoid tar and soot and clogs Please avoid foreign objects cement or...

Page 12: ...ll the smoke pipes of the boiler in short time causing a dramatic decrease on capacity and efficiency of the boiler Please pay special attention to specification of fuel NOTE In order to determine the...

Page 13: ...5 825 950 1215 1620 1750 2130 w1 180 180 250 250 250 250 250 290 220 220 w2 250 250 250 250 250 250 310 310 310 310 D 130 130 160 160 160 180 250 250 350 350 Circulation Flow Return 1 1 1 1 4 1 1 2 1...

Page 14: ...6 CONTROL PANEL...

Page 15: ...s Fan Cycle Increase Button Increases fan speed from 1 to 5 Fan Cycle Decrease Button Decreases fan speed from 1 to 5 Fan Led Indicates that the fan is functioning properly Pump Led Indicates that the...

Page 16: ...fan must be cancelled until the problem is fixed Gas draught of the chimney must be high A simple way to detect this is to cover the entrance of the chimney with a news paper and see if the paper han...

Page 17: ...the sytem water temprature reaches to set values on control thermostat At this value the fan will stop and the circulation pump continues to function In this case you can see what temprature is the b...

Page 18: ...pump might get damaged ATTENTION In case of an electricty cut and when the circulation pump is not functioning the boiler water can reach to a boiling degree since heat transfer will not be done In t...

Page 19: ...aning lid at the back smoke case and clean inside of the smoke case Make sure that it fits properly during remount Close the cleaning lid and turn off moving grill in order to restart the boiler Chimn...

Page 20: ...9 ELECTRIC SCHEME...

Page 21: ...Decrease draught by reinforcement The fan does not stop when it reaches to thermostat value Thermostat is broken Thermostat must be replaced There is tar and soot inside the boiler and chimney Low qua...

Page 22: ...e use of the supporting ring When the boiler lifted up with crane there shouldn t any living being under the boiler Boiler must be carried with its accessories installed on it B CARRYING BOILER ON VEH...