. SAFETY SYSTEM OF THE DEVICE

MAKTEK OMEGA ELECTRIC BOILER ; 

has the following safety features in order to 

ensure the highest level of safety and highest technology.

7

.1 

RCD DEVICE (

SHORT CIRCUIT RELAY

)

In case of short circuit, the relay shuts off the electricity connection and prevents any 

possibility of electruction  and prevents any harm to people or the device.

7

.2 HEATING TANK 

FLOAT

 LEVEL SENSOR (H6)

This sensor prevents the boiler from running without sufficient water inside the heating tank 

therefore avoids any damage to the resistances. In case of low water level, H06 is 

displayed on the device's screen. The air trapped must be completely removed from the air 

vent valve which is placed on top of the device. If the water pressure drops after the air is 

taken, the display shows H03. In this case, water should be added from the filling valve.

7

.3 LOW WATER PRESSURE

If the pressure at the heating circuit is below 0.7 bar, the boiler will not operate and the H3 

warning code will appear on the digital display,preventing damage which causes from 

running without water.

What to Do: 

The heating system pressure is increased by adding water up to the desired 

level by the filling valve. You can view the pressure of the water filled from the manometer.

7

.4 OVERHEAT LIMIT THERMOSTAT

If the water temperature at the heating system is above 95°C, the system energy is cut off 

by the card and the H5 warning code is shown on the digital screen.

What to Do:

 When the water temperature of heating system drops down to 60°C, the 

boiler will start working again. If this failure occurs two times consequently, please call an 

authorized service.

7

.5 FROST PROTECTION

When the temperature in the heating system drops down to 5°C, there is security system 

that automatically activates the resistances When the water temperature reaches 40°C, 

activation of resistances are stopped.

In order for this system to work, the main switch to which the device is connected must be 

switched on and the heating and hot water selector switches must be set to the minimum 

setting.

15

Summary of Contents for Omega 6

Page 1: ...rev no 01 05 2018...

Page 2: ...NS 10 3 7 FILLING WATER TO THE SYSTEM 11 3 8 STARTING UP 11 3 8 1 PRE CONTROLS BEFORE STARTING UP 11 3 8 2 FIRST OPERATION 11 3 8 3 CIRCULATION PUMP PRESSURE CURVE 12 4 FEATURES OF OMEGA ELECTRIC BOIL...

Page 3: ...d this guide carefully This guide is an important source of installation and technical features that you can benefit from It is very important for you autorized services in terms of the information it...

Page 4: ...ation Damage to the furniture or floor or animals resulted from falling objects from device because of vibration Do not climb on the device Personel injury as a result of falling down with device or f...

Page 5: ...ators connected to the system and provides hot water by heat exchanger Installation and services must be in accordance with recent standarts and announced directives Our company is not responsible for...

Page 6: ...2 2 COMPONENTS OF THE BOILER 5...

Page 7: ...ere is no hot water production even when the hot water tap is opened TEST Mode of adjustment by AUTORISED SERVICE during first installation or maintance Users should not use this position during opera...

Page 8: ...rgy cable dimensions should be chosen from the technical specifications table in this manual and must be connected by a qualified electrician WARNING Do not operate the boiler before venting the air f...

Page 9: ...ace must be left around the for the authorized service to intervene in the event of a technical breakdown or maintenance You can find the minimum spaces required for installation in the below diagram...

Page 10: ...e above the capacity of the pump must be avoided You can see the pump capacities from the pump pressure curve When there is a pressure increase at heating system the security ventile operates in order...

Page 11: ...OLS BEFORE STARTING UP A Make sure all air is vented from the system radiators and the boiler and all air vents are closed B Check the system pressure from the manometer Must be 1 2 1 5 bars C Remove...

Page 12: ...ega Boiler Circulation pump has 3 speed options You can choose the required pump speed according to the resistance of your installation You can use the below diagram for deciding the pump speed Water...

Page 13: ...an quickly enter the regime and heat the house Protection against high pressures with 3 bar safety valve Manometer 3 stage circulation pump 1 bar set safety switch protection againts running without w...

Page 14: ...5 TECHNICAL TABLE 13...

Page 15: ...6 ELECTRICITY CONNECTION DIAGRAM 14...

Page 16: ...r the boiler will not operate and the H3 warning code will appear on the digital display preventing damage which causes from running without water What to Do The heating system pressure is increased b...

Page 17: ...ves are switched off there is an automatic by pass system in order to provide of passing of minimum water flow in order to prevent rapid over heating of the boiler 8 MAINTENANCE We recommend that the...

Page 18: ...ansport 7 Damages caused by the use of lime water in hot water circulation ideal water hardness will be 15 20 French hardness 8 First operation and interventions by people other than the authorized se...

Page 19: ......

Reviews: