background image

                                               

ELECTRICAL

PANEL RADIATOR

USING AND INSTALLATION 

MANUAL 

Summary of Contents for TYPE 3100

Page 1: ...ELECTRICAL PANEL RADIATOR USING AND INSTALLATION MANUAL...

Page 2: ...2 SAFETY WARNINGS 3 3 MEASURES AND CAPACITIES 5 4 WALL MOUNTING OF THE RADIATOR 6 5 BEFORE THE FIRST START 9 6 FIRST START 10 7 PROBLEMS AND SOLUTIONS 12 8 SUGGESTIONS FOR ENERGY SAVING 13 9 HEAT TRA...

Page 3: ...tor is heated by the heating elements in the system by heating the heat transfer fluid between the paneLs The heat transfer surface which is expanded by the converters allows obtained heat to pass thr...

Page 4: ...om laundry or other moist plasec Do not mount the device on any water basin in a bath tub and never immerse it in water 9 To stop the operation of the device first set the temperature control knob to...

Page 5: ...WARNING DO NOT use the radiator NEVER in an leaning position IMPORTANT Always operate the radiator with a grounded socket 4...

Page 6: ...3140 2 0 98 300 1400 9 TYPE 4100 1 4 98 400 1000 6 TYPE 4120 1 6 98 400 1200 7 TYPE 4140 2 0 98 400 1400 9 TYPE 5100 1 6 98 500 1000 7 TYPE 5120 1 8 98 500 1200 8 TYPE 5140 2 2 98 500 1400 10 TYPE 60...

Page 7: ...uld be drilled with the measurements in figure 1 and indicated by 1 2 3 4 numbers Vertical hole distances In Figure 1 Horizontal distance between carrier brackets Figure 2 The installation method of t...

Page 8: ...Figure 2 Figure 3 7...

Page 9: ...Figure 4 Figure 5 8...

Page 10: ...ng voltage of the radiator Always connect the radiator to an insulated and grounded power line The mains cable used in the radiator has a cross section of 3 x 2 5 mm and has a resistance for maximum f...

Page 11: ...Once you have made sure that the radiator is properly installed in the wall and that you have read all the information and warnings in this manual put the radiator plug in the prize Switch the power...

Page 12: ...ch radiator temperature corresponds to which of 5 different levels Level Oil Temperature 1 15 C 2 30 C 3 45 C 4 65 C 5 80 C Table 2 When the temperature of the heat transfer fluid in the radiator reac...

Page 13: ...e two safety thermostats in the radiator set to 100 C These thermostats cut off the heating circuit at 100 C fluid temperature in case of overheating of the radiator resulting in a constant current fl...

Page 14: ...he device does not work for a long time the temperature of the room will decrease much more and the appliance will work more to bring the temperature of the room to the desired level of comfort Instea...

Page 15: ...at very high temperatures max 350 C thanks to its additives It is not corrosive toxic and does not require renewal TECHNICAL SPECTS TEST VALUES TEST METHOD Viscosity 40 C cSt 32 35 ASTM D 445 Density...

Page 16: ......