Troubleshooting - Frequently Answered Ques-
tions
MALÅ Easy Locator HDR has been design to be robust and reliable under adverse con-
ditions. If you encounter a mechanical failure that cannot be fixed on site please contract
MALÅ Geoscience or your MALÅ Geoscience representative for advice.
System malfunctions
Most malfunctions are power or data communications related. Before contacting your
local MALÅ Geoscience office or authorized dealer please follow these simple steps.
1
Check battery capacity
Connect the battery to the charger and switch on the charger
at the electrical outlet.The light on the battery charger should
be either yellow or green indicating an operative charge. If
the indicator light is red, continue charging until the charging
cycle is complete, i.e., indicator light turns green.
2
Check connectors
l
Disconnect and reconnect the battery connector in the
MALÅ Easy Locator HDR battery box or RTC battery
bag.
l
Disconnect and reconnect the power cable con-
nectors on the rear of the MALÅ Easy Locator HDR
battery box or RTC bag and the connector on rear of
the antenna.
l
Disconnect and reconnect both ends of the combined
power/data cable between the antenna and the MALÅ
Easy Locator HDR monitor.
l
Check the pulse encoder connector on the rear of the
antenna.
3
Restart MALÅ Easy Locator HDR
Turn off the MALÅ Easy Locator HDR antenna and monitor,
by first selecting
QUIT
from the on-screen menu options on
the monitor, confirm the action by selecting
YES
then push
the power button on the monitor and release quickly. The red
light will then stop blinking and the unit will also emit a click
when turning off. Wait 10 seconds before switching on the
monitor and antenna.
Note:
If the monitor is not responding, turn the unit off by push-
ing the power switch.