background image

NOTICE!

If the feeder cable is damaged, it must be replaced

by its manufacturer or its authorized technical

service or any other personnel qualified at the

same level, in order to avoid any dangerous situa-

tion.

NOTICE!

When the bulbs of the device malfunction, switch

off the circuit breaker and unplug the device's

power plug from the socket. Replace the defective

bulbs immediately (leave bulbs to cool down first),

in order to protect the remaining bulbs against

overloading.

CAUTION!

Accessible components might be heated when

used with cooking devices.

DANGER!

Air outlet pipe of this appliance mustn't be con-

nected in the flue used to discharge the fume gen-

erated by devices that use gas or other fuels.

Damage reasons

CAUTION!

Damage hazard due to corrosion. Always run the

appliance to prevent condensate formation while

cooking. Condensates may cause corrosion

damage. Replace the malfunctioning lamp right

away to prevent overloading of other lamps. Mois-

ture intrusion in electronic parts poses a risk of

damage. Never clean the control elements with a

wet cloth. The surface could be damaged due to a

wrong cleaning process. Clean stainless steel sur-

faces only in their brushing direction. Do not use a

stainless steel cleaner for the control elements.

The surface could be damaged due to aggressive

and abrasive cleaning agents. Never use aggres-

sive and abrasive cleaning agents. There is a risk

of damage due to condensate liquid backflow.

Install the air exit canal with a small downward

inclination (1° inclination) from the appliance.

WARNING AND SAFETY PRECAUTIONS

LETHAL RISK, DANGER OF POISONING 

19.07.2018

USERS MANUAL CHIMNEY HOOD

12

Summary of Contents for Gama K3155.9

Page 1: ...USERS MANUAL CHIMNEY HOOD Assembly instructions Gama K3155 7 Gama K3155 9 Read this manual prior to performing any task...

Page 2: ...279 Nguyen Van Troi Street Ward 10 Phu Nhuan Dist HCM City Telephone 84 28 39975 893 94 Fax 84 28 38447 102 84 28 38633 882 E mail info malloca com Customer Care Hotline 1800 12 12 E mail chamsockh ma...

Page 3: ...6 6 3 Hand Wash 16 7 APPLIANCE POSITION 17 7 1 Installation and Unpacking of the Appliance 17 7 2 Recommendations for Energy Saving 17 8 CONTENT OF PACKAGE 18 9 OVERVIEW OF hood 19 10 ASSEMBLY OF PROD...

Page 4: ...ake sure you also give this guideline and safety data n Disregarding this guideline may result in severe injuries and defects in the device n Please keep in mind that we won t be responsible for the d...

Page 5: ...2 Technical Drawing 25 80 400 20 500 500 698 262 250 M n 90 635 Max 90 1020 440 135 Fig 1 Technical Drawing 19 07 2018 USERS MANUAL CHIMNEY HOOD 5...

Page 6: ...25 80 400 20 500 500 898 262 250 620 97 135 M ax 1020 Fig 2 Technical Drawing 19 07 2018 USERS MANUAL CHIMNEY HOOD 6...

Page 7: ...s when they work for a long time The lamps may burn your hand as they will be hot n Kitchen hoods are manufactured for household use in normal home cooking There is a risk of malfunction in other type...

Page 8: ...od and cooking appliances and cover the flame Never use water to extinguish the fire n When cooking appliances are in operation their accessible parts could be hot n This appliance is not intended to...

Page 9: ...g heaters shower heaters water heaters etc Fig 3 Ventilated goods e g gas oil wood or coal burning heaters shower heaters water heaters take combustion air from the instal lation location and discharg...

Page 10: ...son Operate gas cookers only when there is a cooking pot on them Operating multiple gas cookers simultaneously creates high heat A ventilation device placed over the cookers can be damaged or burned f...

Page 11: ...due to ingress of mois ture in the electronics Do not clean the control components with a wet cloth The surface could be damaged due to a wrong cleaning process Clean stainless steel sur faces only i...

Page 12: ...AUTION Damage hazard due to corrosion Always run the appliance to prevent condensate formation while cooking Condensates may cause corrosion damage Replace the malfunctioning lamp right away to preven...

Page 13: ...hrough the external wall a tele scopic wall safe must be used Ventilated air mode Absorbed air is cleaned by the grease filters and an active carbon filter and then it is transferred back to the kitch...

Page 14: ...filters should be attached to the product regardless of using a carbon filter or not Do not use the product without an oil filter 5 1 AF 100 Carbon Filter Replacement The device you have bought is sui...

Page 15: ...sive cleaning agents containing sand soda acid or chlorine n Clean the stainless steel surfaces in their brushing direction only n Do not use stainless steel cleaning agents and wet clothes for contro...

Page 16: ...olour This has no effect on the function of the metal grease filter n Do not clean too dirty metal grease filters together with utensils in the dishwasher n Place the metal grease filters loosely and...

Page 17: ...ll be reported to the dealer too n Do not allow children to play the with packaging materials 7 2 Recommendations for Energy Saving n Replace the carbon filters on a regular basis n Regularly clean yo...

Page 18: ...Adapter Option 6 Inner Flue Connection Plate 7 User Manual 8 Installation Template 9 Product Hanging Plate 10 6mm Plastic Dowel 11 10 mm Plastic wall plug 12 5 5x60 Wall Mount Screw 13 M5x35 Product...

Page 19: ...9 OVERVIEW OF hood 1 Internal Flue 2 External Flue 3 Glass 4 Cooker Lighting 5 Control Panel 6 Filter Fig 11 OVERVIEW OF THE HOOD OVERVIEW OF hood 19 07 2018 USERS MANUAL CHIMNEY HOOD 19...

Page 20: ...he wall at the specified height See the minimum and maximum distances intended for the worktop in the assembly pattern and drill holes A B and C with the dimensions specified in the template Fig 12 3...

Page 21: ...3 150 mm Plastic Flue for models that don t feature self flue exhaust 4 Body Place the 150 mm flue adapter on the product body and install it with 3 5x9 5 rysb screw Fig 13 Models that feature self fl...

Page 22: ...rectly affixed to the wall under the cover or points E and F are marked after performing a measurement n Drill points E and F with 6mm drill bit and insert 6mm plastic wall plugs 10 Insert the flue co...

Page 23: ...mer function is activated the relevant button symbol will flash for 15 mins Then 15 minute timer function will be activated and the product will turn off automatically after 15 minutes After the activ...

Page 24: ...ng the lamp To find out the power rating used in the product see the declaration label in the product Only self protection tungsten halogen lamp or self protection metal halide lamp must be used For r...

Page 25: ...wer connection Mains voltage must be 220 240 V and product must be plugged into a grounded socket Illumination lamp does not operate Check the power connection Mains voltage must be 220 240 V and prod...

Page 26: ...cartridge filter should be washed once a month under normal conditions It Does Not Discharge Air in flueless use Check The Carbon Filter In products that work with carbon filters carbon filter must be...

Page 27: ...ulation on Electro magnetic Compliance and 2014 35 EC Regulation on Low Voltage Devices LVD Directives This device complies with the Directive on the Control of Waste Electrical and Electronic Equipme...

Reviews: