The appliance has been manufactured as a class
I
, therefore earth cable is
necessary.
The connection to the mains is carried out as follows:
If not provided, connect a plug for the electrical load indicated on the
description label. Where a plug is provided, the cooker hood must be installed
in order that the
plug is easily accessible.
An omnipolar switch with a minimum opening of 3mm between contacts, in
line with the electrical load and
local standards, must be
the appliance
placed between
and the network in the case of direct connection to the
electrical network.
•
The minimum distance between the support surfaces of the cooking pots on
the cooker top and the lowest part of the cooker hood must be at least 75 cm.
If a connection tube composed of two parts is used, the upper part must be
placed outside the lower part.
Do not connect the cooker hood exhaust to
the same
conductor used to circulate hot air or for evacuating fumes
from other appliances generated by other than an electrical source.
Before proceeding with the assembly operations, remove the anti-grease
filter(s) (Fig.12) so that the unit is easier to handle. In the case of assembly
of the appliance in the suction
version prepare the hole for evacuation
of the air.
•
Hood assembly
Remove the structure from the packaging and separate the upper part from
IEC227
L=live
Brown
N=neutral
Blue
E=earth
Green/Yellow
• Electric Connection