MAINTENANCE INSTRUCTIONS

GENERAL SAFETY

1. Always shut off the gas supply and make sure that the heater is cool before starting

any servicing operation.

2. Always check for leaks after servicing.

3. Always check for correct combustion and ventilation air flow. The flow of combustion

air and ventilation air must not be obstructed.

4. Always check that the appliance area is clear and free from combustible materials, gasoline, and

other flammable vapors and liquids.

PERIODIC CHECKS

1. Keep the burner and control compartment clean by brushing and vacuuming at least once a year.

2. The flame pattern should be checked periodically.  The flame color should be blue with yellow tips.

If needed adjust the air shutter to provide a proper flame.  See Figure F.

3. A qualified service person should Inspect the appliance vent system prior to use and at least

annually, to ensure that the flow of combustion air is not obstructed.

4. If you are unsure how to perform these maintenance procedures have a qualified field service

person check the unit at least annually.

NOTE:

 During the first few fires the odor of paint or oils remaining from manufacturing are likely to

release an odor.  This is normal and will stop as soon as the paint has cured.

5. If for any reason a log should break it must be replaced with the same log.  See the log diagram

for the exact replacement log needed.  The position of the logs must be as shown in the diagram.

CARE OF FINISH

1.  The matte black finish can be wiped clean with a damp cloth.  If the finish becomes marred or

scratched it may require touch up spraying.  Use Stove Bright Flat Black spray.  This is available

from your dealer or from Malm direct.

2. If your unit is porcelain enamel use any glass cleaner to wipe the unit clean.  Minor scratches can

be  polished  with  most  nonabrasive  auto  polish.    If  the  porcelain  should  become  chipped  or

severely damaged an enamel touch up is available from your dealer or Malm direct.

Page - 8

Summary of Contents for ZIRCON 34

Page 1: ... gas supplier from a neigh bor s phone Follow the gas supplier s instruc tions If you cannot reach your gas supplier call the fire department FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vi cinity of this or any other appliance WARNING Improper installation adjustment alteration service or mainte nance can cause injury or property damage Refer to this m...

Page 2: ...ler immediately Do not install this appliance using damaged parts GAS SUPPLY For use with natural gas or propane gas depending on which option you have ordered The minimum inlet gas supply pressure for the purpose of input adjustment Natural Minimum 5 5 Water Column 1 4 kPa Maximum 10 5 Water Column 2 6 kPa Propane Minimum 11 Water Column 2 75 kPa Maximum 13 Water Column 3 25 kPa a The supply syst...

Page 3: ...appliances equipped with a draft hood The damper saves energy by preventing the escape of heated air through the venting system when the appliance is not in use It has four quadrants of bimetal which remain closed when the appliance is not in operation Upon ignition of the appliance the hot flue gases reach the damper causing the quadrants to flex thereby opening the vent passage within a short pe...

Page 4: ...arances around the opening There must be adequate accessibility clearance for servicing and proper operation Page 4 CAUTION Any safety screen or guard removed for servicing an appliance must be replaced prior to operating the appliance Clothing or other flammable material should not be placed on or near the appliance Figure 1 Figure 2 CLEARANCES SIDEWALL AND BACKWALL INSTALLATION Unit to Sidewall ...

Page 5: ...ING REQUIREMENTS Use a B vent masonry or class A chimney Follow all manufacturers requirements and local building codes If you are using B vent utilize the support box supplied with unit GAS LINE ATTACHMENT The gas supply line must be installed at the rear right side of the gas unit This supply line must be a minimum of 1 2 black iron type pipe A separate manual shut off valve should always be use...

Page 6: ...ort box The cleat will lock into place as the pipe is pushed up into the support box 2 Slip one of the mid sections over the slip connector Slide the mid section up only enough to allow the placement of the next section of pipe between the unit and the bottom of the mid pipe that was placed onto the slip connector 3 Place the remaining mid section into the collar on top of the unit 4 Pull the mid ...

Page 7: ...en under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS 1 STOP Read the safety information above on this label 2 Push in the control knob slightly and turn clockwise to OFF NOTE Knob cannot be turned from PILOT to OFF unless knob is pushed in slightly D...

Page 8: ...e flow of combustion air is not obstructed 4 If you are unsure how to perform these maintenance procedures have a qualified field service person check the unit at least annually NOTE During the first few fires the odor of paint or oils remaining from manufacturing are likely to release an odor This is normal and will stop as soon as the paint has cured 5 If for any reason a log should break it mus...

Page 9: ...ot AssemblySit 0145003 11 MV 11 Piezo Lighter Electrode 12 MV 12 Pilot Hood 13 MV 13 Thermocouple Sit 0290136 6 13 12 11 10 9 8 7 5 3 2 1 The pilot flame adjustment is located behind the valve cover Remove the cover screw and cover Locate the pilot adjustment at the upper right hand of the valve The pressure regulator adjustment is located on the bottom of the valve CAUTION Only trained and qualif...

Page 10: ...x 13 PilotFlame Malm Fireplaces Inc Malm Fireplaces Inc Malm Fireplaces Inc Malm Fireplaces Inc Malm Fireplaces Inc 368 Yolanda Avenue Santa Rosa Ca 95404 707 523 7755 800 535 8955 Fax 707 571 8036 email info malmfireplaces com Minimum 1 4 opening Logs have notches for proper placement on grate ...

Reviews: