ASSEMBLY
Inserting/Replacing the Batteries
Alkali-manganese batteries are recommended for
the measuring tool.
To open the battery lid
10
. Insert the batteries pro-
vided. When inserting, pay attention to the correct
polarity according to the representation on the
inside of the battery compartment.
Always replace all batteries at the same time. Only
use batteries from one brand and with the identi-
cal capacity.
•
Remove the batteries from the measuring tool
when not using it for extended periods. When
storing for extended periods, the batteries can
corrode and self-discharge.
OPERATION
Initial Operation
•
Protect the measuring tool against moisture and
direct sun light.
•
Do not subject the measuring tool to extreme
temperatures or variations in temperature.
As an example, do not leave it in vehicles for
longer periods. In case of large variations in
temperature, allow the measuring tool to adjust
to the ambient temperature before putting it
into operation.
•
Avoid heavy impact to or falling down of the
measuring tool. Damage to the measuring tool
can impair its accuracy.
•
Switch the measuring tool off during transpor-
tation.
Switching On and Off
To switch on the measuring tool in line operation,
push the On/Off switch
1
forward. To switch on
the measuring tool in point operation, push the
On/Off switch
1
back.
Immediately after switching on, the measuring
tool sends a laser beam out of outlet opening
5
(line operation) or
6
(point operation), depending
on the selected operating mode.
•
Do not point the laser beam at persons or
animals and do not look into the laser beam
yourself, not even from a large distance.
To switch off the measuring tool, push the on/off
switch
1
to the centre position.
•
Do not leave the switched on tool unattended
and switch the tool off after use. Other persons
could be blinded by the laser beam.
When not using the measuring tool, switch it off
in order to extend the battery life.
Levelling Functions
Note:
The specified levelling accuracy applies for
the alignment of the laser beam with reference to
the spirit levels
3
and
4
.
If spirit level leaks, soak up with appropriate ab-
sorbent material and dispose of safely. Spirit levels
contain flammable liquid that may cause respira-
tory tract, eye and skin irritation.
Position the Tool (see figure B)
For precise alignment with the spirit levels, the
position of the tool is important.
The specified levelling accuracy is only achieved
when the tool is correctly positioned:
For horizontal alignment with spirit level
4
, the
laser outlet opening for line operation
5
must be
horizontal and the aluminium supporting surface
2
of the measuring tool must face downward.
For vertical alignment with spirit level
3
, the laser
outlet opening for line operation
5
must face
upward and the aluminium supporting surface
2
of the measuring tool must face sideward.
Alignment with Laser (Line Operation)
Fasten the measuring tool to wall holder
13
(see
“Fastening/Aligning with the wall holder”), place
it against a wall or fasten it to an other magnetic
surface with the magnets
9
.
Horizontal Alignment (see fig. C-D):
The laser outlet opening for line operation
5
must
be horizontal and the aluminium supporting sur-
face
2
of the measuring tool must face downward.
Horizontally align the measuring tool with spirit
level
4
. As an example, you can align picture
frames or shelves alongside the horizontal laser
line.
Note:
Horizontal alignment with the laser line is
only possible on the surface, against which the
measuring tool was placed. Even when the meas-
uring tool was aligned with the spirit level, the
laser line on a transverse wall does not necessarily
run horizontal, and is thus not suitable for level-
ling.
Vertical Alignment (see fig. D):
The laser outlet opening for line operation
5
must
face upward and the aluminium supporting sur-
face
2
of the measuring tool must face sideward.
Vertically align the measuring tool with spirit level
3
. As an example, you can align top and base
cabinets alongside the vertical laser line.
Alignment Off of Reference Points (see fig. E):
Turn the measuring tool to any required angle in
order to align the laser line alongside your refer-