4
controL PaneL
1. Main Switch
– If you switch on the unit on the main switch, it will run
in a fully automatically operation.
2. Power Lamp
– If you switch on the main switch, a green control-lamp
“power” will illuminate.
3. Full Water Lamp
– When the water tank is full, this yellow control-
lamp “full water” will illuminate.
4. Hour Counter
– the collect time of operation will be recorded by an
hour counter.
DeScrIPtIon of functIonS
Switch on the unit. the green pilot lamp illuminates. the ventilation fan
sucks in the moist ambient air via the air filter, the evaporator and the
condenser. Heat is extracted from the ambient air at the cold evaporator.
the air is cooled to below the dew point, and the water vapour contained
in the air is accumulated as condensate water on the evaporator fins and
then drops down into the water tank. as a low temperature of ambient
air is sucked, the water vapour becomes to hair-frost on the evaporator
fins. When the temperature sensor measures a specific low value of the
evaporator’s surface, a timer is activated with a delay of about 30 minutes.
If during this period the evaporator’s temperature does not rise again, the
refrigeration cycle will switch to hot gas defrost after the time reach. Dur-
ing the defrost cycle, the ventilation fan is off. as it has defrosted and the
oPeratInG DeScrIPtIon
this unit has been designed for automatic operation and problem-free air
dehumidification. this unit works according to the air condensation prin-
ciple and is equipped with a hermetically sealed refrigeration system, as
well as with a maintenance-free ventilator. the water container include an
overflow-protection equipped with a float-switching device and a drain-
age hose-nipple for continuous operation.