5
temperature at the
sensor rise again,
the unit will switch
back to normal
dehumidifying op-
eration. When the
room temperature
is high enough, the
evaporator surface
never becomes as
cold as to allow the
formation of hair-
frost; consequently
defrosting is not
necessary. the
dehumidified and
cooled down air is
reheated at the condenser (heat exchanger), and then it is blown out. the
conditioned dry air is mixed with the ambient air. Due to the continuous
circulation of the ambient air through the unit, the relative humidity of air
in the place of installation is continuously reduced.
InStaLLatIon
Install the unit in a stable and horizontal position to ensure the trouble-
free drainage of condensate water.
• Install the unit in the middle of the room, if possible, to ensure optimal
air circulation.
• Make sure that the air can be freely sucked in at the front of the unit
and blown out from its rear part.
• Make sure to maintain a minimum distance of 60 cm to the wall.
• Do not install the unit directly near radiators or other heat sources.
• Do not install the unit in a dust-laden environment.
• Keep the room to be dehumidified closed, so that outside air cannot
penetrate into it.
• frequently opening windows or doors, must be avoided as far as pos-
sible.
• the unit performance will vary depending on room temperature and
relative humidity.
ambient air
dehumidified air
fan & motor
condenser
evaporator
air filter
floater
water tank
compressor
Schematic diagram of function