7
HanDLInG of Water tanK
Depending on the air temperature and the relative air humidity the con-
densed water drips either continuously or only during the defrosting phase
into the condensate tank.
the condensate water tank is located on the front behind a lock door-
cover.
In the water tank there is a floater, which interrupts the dehumidification
operation by means of a micro switch when the tank is full.
the unit stops working and the yellow control lamp a on the control panel
illuminates.
Please empty the water tank as follows:
1. Switch off the unit.
2. open the lock door-cover and lift the container
slightly and then pull it carefully forward to
remove it.
3. open the sliding (see sketch) and pour out the
water.
NOTE: When the unit has been switched off, the
evaporator can further defrost through the ambi-
ent temperature. Make sure that condensate water
does not continue dripping!
Installation of the water tank:
1. Wipe off the water tank with a clean cloth be-
fore you replace it.
2. Please install the cleaned tank carefully.
3. Make sure that the little filler bung is in the
hose nipple (as shown on the picture on next
page).
4. close the door-cover. the unit will only re-start
if you close the lock cover correctly.