8
contInuouSLy oPeratIon WItH HoSe connectIon
the condensate water tank is equipped with a drain nipple. after you
have removed the filler bung you can connect a standard water hose (not
supplied).
a connection of a water hose allows you a continuously operation.
1. open the door-cover and remove the filler bung from the tank.
2. fit the water hose on the drain nipple.
3. Lead the water hose through the hole, which is located on the left side
of the side plate.
4. close the lock door-cover with a little push.
5. Lead the condensate water into a drain hole.
Important! Make sure that the discharge hose is not warped upwards.
MaIntenance
regular care and maintenance will ensure the dehumidifier’s long useful
life and trouble-free operation. the refrigeration system is hermetically
sealed and contains no user-serviceable parts. It may only be repaired by
authorized specialist facilities. the unit should be inspected and cleaned
thoroughly after each long period of operation, at a minimum once a year.
Note! Always remove the plug from the power socket before carrying out
any cleaning or maintenance operations.
• Keep the unit free of dust and other deposits.
• clean the unit only with a soft dry or dampened cloth.
• Do not use a water jet.
drain nipple
11 mm
filler bung