13
Visit us at: www.mpurifier.com
For Question Call: 800.470.4201
MAMMOTH xC User Manual
CLEANING & MAINTENANCE
When the air purifier no longer produces enough ozone to be effective, the ozone plate
should be cleaned (unless it has burnt spots, then the ozone plate should be replaced). A
good rule of thumb is to clean the ozone plate every month if used continuously.
To clean the ozone plate, first turn the unit OFF and UNPLUG from outlet. Then remove
the ozone plates from back of unit. Pull plates firmly in the center to remove from the
slot. With plate firmly supported in the hand apply a solution of warm water and ammonia
(50/50 solution is suggested) or a strong grease cutting detergent. Scrub with a stiff brush
if necessary. Be careful not to drop the plate or scrub off the silicon. Clean both the metal
screen and the ceramic tile. Rinse plate in hot water and DRY COMPLETELY before
installing. If available you may use a hair dryer to dry the plate. Reinstall plate, making sure
it is secured and flush with the back of the unit.
If the ozone generator is making excessive noise or excessive sparks is visible, ozone plate
should be replaced (even if no burnt mark is present)
.
CAUTION: Turn Power Switch OFF first before doing any cleaning or
maintenance. This includes filter replacement, UV lamps replacement
and ozone cleaning or replacement.