MAN B&W
12.07
Page 1 of 2
MAN Diesel
MAN B&W MC/MCC, ME/MEC/MEGI/ME-B engines
198 40 567.3
Components for Jacket Cooling Water System
The sensor is to be located at the outlet from the
main engine, and the temperature level must be
adjustable in the range of 7090 °C.
Jacket water preheater
When a preheater, see Fig. 12.05.01, is installed in
the jacket cooling water system, its water flow, and
thus the preheater pump capacity, should be about
10% of the jacket water main pump capacity.
Based on experience, it is recommended that the
pressure drop across the preheater should be
approx. 0.2 bar. The preheater pump and main
pump should be electrically interlocked to avoid
the risk of simultaneous operation.
The preheater capacity depends on the required
preheating time and the required temperature
increase of the engine jacket water. The tempera-
ture and time relations are shown in Fig. 12.08.01.
In general, a temperature increase of about 35 °C
(from 15 °C to 50 °C) is required, and a preheating
time of 12 hours requires a preheater capacity of
about 1% of the engine`s nominal MCR power.
Deaerating tank
Design and dimensions of the deaerating tank
are shown in Fig. 12.07.01 ‘Deaerating tank‘ and
the corresponding alarm device is shown in Fig.
12.07.02 ‘Deaerating tank, alarm device‘.
Expansion tank
The total expansion tank volume has to be ap-
proximate 10% of the total jacket cooling water
amount in the system.
Fresh water treatment
The MAN Diesel recommendations for treatment
of the jacket water/freshwater are available on re-
quest.
Jacket water cooling pump
The pumps are to be of the centrifugal type.
Jacket water flow ............... see ‘List of Capacities’
Pump head ...................................................3.0 bar
Delivery pressure ...................depends on position
of expansion tank
Test pressure ...................... according to class rule
Working temperature, ............. 80 °C, max. 100 °C
The flow capacity must be within a range from
100 to 110% of the capacity stated.
The stated capacities cover the main engine only.
The pump head of the pumps is to be determined
based on the total actual pressure drop across
the cooling water system.
Freshwater generator
If a generator is installed in the ship for produc-
tion of freshwater by utilising the heat in the jacket
water cooling system it should be noted that the
actual available heat in the jacket water system is
lower than indicated by the heat dissipation figures
given in the ‘List of Capacities‘. This is because
the latter figures are used for dimensioning the
jacket water cooler and hence incorporate a safety
margin which can be needed when the engine is
operating under conditions such as, e.g. overload.
Normally, this margin is 10% at nominal MCR.
The calculation of the heat actually available at
specified MCR for a derated diesel engine is stat-
ed in Chapter 6 ‘List of Capacities‘.
For illustration of installation of fresh water gen-
erator see Fig. 12.05.01.
Jacket water thermostatic valve
The temperature control system is equipped with
a threeway valve mounted as a diverting valve,
which bypass all or part of the jacket water
around the jacket water cooler.
Summary of Contents for B&W S50MC-C8-TII
Page 4: ......
Page 10: ......
Page 18: ......
Page 19: ...MAN B W MAN Diesel Engine Design 1 ...
Page 20: ......
Page 35: ...MAN B W MAN Diesel Engine Layout and Load Diagrams SFOC 2 ...
Page 36: ......
Page 52: ......
Page 64: ......
Page 65: ...MAN B W MAN Diesel Turbocharger Selection Exhaust Gas By pass 3 ...
Page 66: ......
Page 72: ......
Page 73: ...MAN B W MAN Diesel Electricity Production 4 ...
Page 74: ......
Page 106: ......
Page 107: ...MAN B W MAN Diesel Installation Aspects 5 ...
Page 108: ......
Page 146: ......
Page 170: ......
Page 171: ...MAN B W MAN Diesel List of Capacities Pumps Coolers Exhaust Gas 6 ...
Page 172: ......
Page 192: ......
Page 193: ...MAN B W MAN Diesel Fuel 7 ...
Page 194: ......
Page 208: ......
Page 209: ...MAN B W MAN Diesel Lubricating Oil 8 ...
Page 210: ......
Page 223: ...MAN B W MAN Diesel Cylinder Lubrication 9 ...
Page 224: ......
Page 233: ...MAN B W MAN Diesel Piston Rod Stuffing Box Drain Oil 10 ...
Page 234: ......
Page 236: ......
Page 237: ...MAN B W MAN Diesel Central Cooling Water System 11 ...
Page 238: ......
Page 243: ...MAN B W MAN Diesel Seawater Cooling System 12 ...
Page 244: ......
Page 254: ......
Page 255: ...MAN B W MAN Diesel Starting and Control Air 13 ...
Page 256: ......
Page 262: ......
Page 263: ...MAN B W MAN Diesel Scavenge Air 14 ...
Page 264: ......
Page 276: ......
Page 277: ...MAN B W MAN Diesel Exhaust Gas 15 ...
Page 278: ......
Page 292: ......
Page 293: ...MAN B W MAN Diesel Engine Control System 16 ...
Page 294: ......
Page 309: ...MAN B W MAN Diesel Vibration Aspects 17 ...
Page 310: ......
Page 324: ......
Page 325: ...MAN B W MAN Diesel Monitoring Systems and Instrumentation 18 ...
Page 326: ......
Page 348: ......
Page 349: ...MAN B W MAN Diesel Dispatch Pattern Testing Spares and Tools 19 ...
Page 350: ......
Page 388: ......
Page 389: ...MAN B W MAN Diesel Project Suppport and Documentation 20 ...
Page 390: ......
Page 399: ...MAN B W MAN Diesel Appendix A ...
Page 400: ......