Commissioning and operation
56
The following light-emitting diodes function continuously:
D
Power on:
Diagnosis unit is receiving voltage
D
Ignition:
Ignition is on
D
Serial data activity:
Data interchange at the bridge.
If this fails, no more data is displayed on the bridge, neither
on the display (Display MMDS-D08/L /LC).
If the following light-emitting diodes light up, there is a fault
D
Diagnostic unit failure:
The diagnosis unit is defective
D
Sensor failure
A sensor is defective. The measurement point of the
defective sensor flashes with the same frequency as
“Sensor failure“
D
Speed sensor failure:
Defective engine speed input
D
Remote slow down:
Remote reduction of speed.
Alarm at other engine. The defective engine reduces the
intact engine.
This prevents a curving manoeuvre in the case of an alarm.
Shutting down
Do not switch off engine immediately operation at high loads, but let it idle for about 5
minutes to achieve a temperature equalisation.
Set deck switch to “Neutral” and switch off the engine at the ignition key.
Remove key from starting lock.
Danger:
Ensure that the engine cannot be started by unauthorized persons