TDC
BDC
1
2
3
4
5
6
7
Limit values
Service Data
Dimensions
148
Valve timing
1 = engine direction of turn
2 = intake valve opens 24
°
before TDC
3 = exhaust closes in TDC
4 = exhaust valve opens 60
°
before
BDC
5 = intake valve closes 36
°
after BDC
6 = Exhaust open for 240
°
7 = Inlet open for 240
°
The degrees specified refer to the crank-
shaft angle
Compression pressures
good
above 26 bar
permitted
23
−
26 bar
repair required
below 23 bar
Pressure difference (between the individual cylinders)
max. 4 bar