Commissioning and operation
31
Setting possibilities
Further settings can be made by pressing the button:
D
Selection of illumination intensity in 8 steps
D
Selection of display unit in metric or English units
D
Selection of transmitters for the analogue inputs
Selection of illumination intensity
If you keep the push-button pressed for 4 seconds, the scroll bar for the illumination setting appears.
By repeatedly pressing the key, you can change the illumination of the tachometer and the connected bus
display in 8 steps. The display jumps back to the normal operating mode 8 seconds after the last time the
button is pressed. The illumination setting is retained even after switching the power supply off and on
again. Please note that setting of the illumination is possible only if external illumination is set to “Internal"
in the settings menu, see page 32.
Basic Settings
The basic settings necessary for perfect operation can be selected in the settings. These are obtained by
pressing and holding the button while switching on the power supply of the display.
Display Units:
Selection of display unit
Screens on / off:
Selection of display
Simulator Mode:
activation of simulator mode
Exit Setup:
exits the setting menu
In order to change a value (e.g. from NO to YES) press the button briefly.
In order to not change a value, keep the button pressed until the set value flashes once. Then release the
button immediately. This adopts the displayed setting. If the button is not pressed, the displayed setting is
automatically adopted after 10 seconds.
Selection of the display units)
The values for temperatures and pressures can be displayed alternatively in the units
°
C/bar
(METRIC) or
°
F/psi (ENGLISH). Selection of the units is carried out as follows:
In the example shown the unit is changed from METRIC to ENGLISH.
Press key
DISPLAY UNITS
METRIC
DISPLAY UNITS
ENGLISH