Operation
54
Carefully read the Operating Instructions before starting any work!
This is especially valid for the chapter on General Safety Instructions
and the safety instructions in each of the chapters.
7.4.2
Monitoring Operation
IMPORTANT!
Do not overload engine.
If faults occur, investigate and solve them immediately to prevent major damage from oc
curring!
The oil pressure and the coolant temperature are constantly monitored during engine operation.
If the limits are exceeded or gone below, the engine will be automatically shut off.
7.4.3
Stopping in an Emergency
An emergency-off button, for shutting down the system in an emergency, must be installed for each engine.
7.4.4
Engine Shut Off
Deceleration of the engine from 100% to 0% is made using a ramp in a time interval of at least 3 minutes.
This minimises the thermal load on the engine block.
DANGER!
Risk of fire caused by unburned gases!
The gas supply is always to be turned off before the ignition system is turned off. This en
sures that no unburned gas can reach the exhaust system.
For this reason:
S
If there is damage to the engine shutoff device, do not shut off engine by shutting off igni
tion system.
S
Close main gas valve.
S
Turn off ignition system after engine is at a standstill.
S
Ensure that the engine cannot be started by unauthorised persons.
1. Shut off gas supply.
2. The engine stops running.
3. After waiting 5 seconds, turn off ignition system and control system.
NOTE!
The coolant pump will run on for approx. 5 minutes after engine has stopped.
This minimises the thermal load to the engine block.