Disposal

Medical equipment and devices should be disposed of in proper containers that meet 
Environmental Protection Agency standards. Check with local State Laws & 

  

Regulations to see what is required in your state or contact your local 

 

 

representatives.

Maintenance and Replacement Parts:

The 

Nature’s Bond

 device contains no user serviceable parts inside: Opening or 

tampering with this device will void the warranty. In the event the 

Nature’s Bond

 

device requires repairs, it should be returned to the medical equipment 

company or to Manamed directly. Expected lifetime of the device is 

two years under normal use. 

Warranty Information

ManaMed warrants its 

Nature’s Bond Breast Pump

, excluding accessories  

(“Breast Pump”) to be free from defects in workmanship and materials for a period 
of one (1) year from the date Device is delivered to the original purchaser (“Breast 
Pump Warranty Period”).  In addition, ManaMed warrants its Breast 
Pump Accessories, (de

fi

ned as bottles, caps, tubing sets, carrying case and breast 

shields) (“Accessories”), to be free from defects in workmanship and materials for a 
period of ninety (90) days from the date the Accessories are delivered to the original 
purchaser (“Accessories Warranty Period”). This Limited Warranty is extended only 
to the original purchaser (de

fi

ned as the original purchaser from the distributor) and 

is non-transferable.  ManaMeds’ sole obligation under this Limited 

 

Warranty shall be, at its sole discretion, to repair or replace a Device which is 

 

defective in either workmanship or material.  This is the sole remedy of the 
Purchaser.  In addition, this Limited Warranty does not cover any Device which may 
have been damaged in transit or has been subject to misuse, neglect, or accident; or 
has been used in violation of ManaMeds’ instructions, including, 

 

without limitation, the instructions contained in the Operation Manual.

Troubleshooting

Low or no suction:

   Check valve and tubing for chips or cracks. If flawed, replace valve or tubing 

 

respectively.

   Inspect breast shield and breast shield connector to make sure there are no cracks 

and they are securely attached to each other.

  Check all connections to ensure that they are tight and secure.

Will not power on:

  Check to make sure the outlet is proper and functioning.

Summary of Contents for Nature's Bond NB603

Page 1: ...www manamed com 888 508 0712 Breast Pump Instructions For Use Model NB603 IFUNB603 Rev A 10132020...

Page 2: ...ds Recycled Manufacturer Catalog Model Number Protected against solid foreign objects of 12 5mm and greater and vertically falling water drops IP21 ATTENTION Consult ACCOMPANYING DOCUMENTS This symbol...

Page 3: ...perating Cycle At Expression Stage Approx 60 times min AC Input Voltage Range 100 240VAC Operating Frequency 47 63HZ Input Current 600mA Max Output Current 2A Max Output Power 18W DC Output Voltage Ra...

Page 4: ...ssary when used near children or people with disabilities Use product only for its intended use Do not use attachments not recommended by the manufacturer Keep cord away from heated surface Never use...

Page 5: ...the power source Plug the power adaptor into the breast pump first then into the power source Do NOT use antibacterial or abrasive cleaners detergents when cleaning breast pump or breast pump parts N...

Page 6: ...ondbreast pump is intended for lactating women to express and collect milk from their breasts to complement breast feeding Description Nature s Bondis a personal use electric breast pump that has two...

Page 7: ...soft brush 6 Rinse all separated parts with clear water 7 Allow all parts to air dry in a clean area 8 Store dry parts when not in use When using dishwasher 1 Wash all separated parts on top rack of d...

Page 8: ...th no areas of hardness Device Operation Wash hands before touching breast pump kit and breasts Avoid touching the inside of containers or lids Always inspect breast shields connectors valves and tubi...

Page 9: ...ealed bottle in a bowl of warm water for 20 minutes to bring it to body temperature If you are adding expressed breast milk to a container of already frozen breast milk make sure to add a lesser amoun...

Page 10: ...ories to be free from defects in workmanship and materials for a period of ninety 90 days from the date the Accessories are delivered to the original purchaser AccessoriesWarranty Period This LimitedW...

Page 11: ...AMED SHALL NOT BE LIABLE FOR ANY EXEMPLARY OR PUNITIVE DAMAGES Appendix 1 Important information regarding Electro Magnetic Compatibility EMC With the increased number of electronic devices such as PC...

Page 12: ...t 3 Guidance and Manufacturer s Declaration Electromagnetic Emissions The MODEL NB603is intended for use in the electromagnetic environment specified below The customer or the user of the MODEL NB603s...

Page 13: ...5s 3 A m 6 kV contact 8 kV air 2 kV for power supply lines and dc lines 1 kV line s and neutral 2 kV line s to earth 5 UT 95 dip in UT for 0 5 cycle 40 UT 60 dip in UT for 5 cycles 70 UT 30 dip in UT...

Page 14: ...he higher the frequency range applies NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people a...

Page 15: ...requency of transmitter m output power of transmitter W 0 01 0 1 1 10 100 150 kHz to 80 MHz d 1 2 P 0 12 0 38 1 2 3 8 12 80 MHz to 800 MHz d 1 2 P 0 12 0 38 1 2 3 8 12 800 MHz to 2 5 GHz d 2 3 P 0 23...

Page 16: ...www manamed com 888 508 0712...

Reviews: