33
White
Brown
Blue
Orange
6
9
1
3
Interface Module Jumper
(TK8200)
Always set the jumper
located inside the
Interface Module on
N.O (Normally Open)
Black & White
White
Black & White
White
PHOTO051
P
HOTO008
FOR MOMENTARY CONTACT TO CLOSE (B2 WIRING), PLEASE REFER TO INSTRUCTION BELOW
1
3 9
9
1
6
NOTE
WARNING
•
Wall control(s) must be located so
that the door is within sight of the
user.
•
If momentary contact (B2 mode) is
used, an external reversing device
must be install.
C2
B2
C2 wiring:
momentary contact to open
and stop, constant pressure to close
with 3 push button station. Activation
of safety device will reverse the door
during closing. Auxiliary devices to
function as an open/control and to
reverse the door during closing.
B2 wiring:
momentary contact to
open, close and stop with 3 push
button station. Activation of safety
device will reverse the door during
closing. Auxiliary devices to function
as an open/close control and to
reverse the door during closing.
C2 to B2
Move red wire from #5 to #7
B2 to C2
Move red wire from #7 to #5
WARNING
Motorized doors can cause serious
injuries or death. Manaras strongly
recommends the use of entrapment
protection systems, especially in
the case of momentary contact to
close such as with B2 wiring or
timer to close.
Summary of Contents for Opera MGT
Page 14: ...14 6 MGT exploded view...
Page 25: ...25 7 10 Single phase ECB wiring diagram...
Page 26: ...26 7 11 3 Phase ECB wiring diagram...
Page 38: ...38 9 6 Single phase hardwired wiring diagram...
Page 39: ...39 9 7 3 phase hardwired wiring diagram...
Page 41: ...41 NOTES...
Page 42: ...42 NOTES...
Page 43: ...43 NOTES...
Page 44: ...44 BOOK169 REV 7 2010 08 29 Reg T M of 9141 0720 Qu bec Inc OPERA...