4. INSTALLATION
Wheel balancer installation should be done only by qualified Service personnel.
4.1.
REQUIREMENTS
4.1.1.
LOCATION
The Wheel balancer should not be installed outdoors, in moist rooms, at
hazardous locations, or in the vicinity of explosives or flammable liquids.
Choice of a suitable location is the owner's responsibility
4.1.2.
SPACE REQUIREMENTS
The floor should be properly leveled beneath the Balancer and should
be free of heavy equipment vibrations.
The clearances from side walls and roof should be adequate so that the
Wheel guard can be opened completely and the mounting / removal of
wheels can be done easily as shown in Fig.1.
Fig. 1
4.1.3.
POWER REQUIREMENTS
For 230V 50/60Hz operation: Single Phase, 230VAC ±10%, 50/60Hz +N +PE
For 110V 60/50Hz operation: Single Phase, 110VAC ±10%, 60/50Hz +N +PE
Supply to the equipment must be connected through a CE certified MCB with
ratings as given below:
For 230V 50/60Hz operation: Two pole, Type C, 6A MCB
For 110V 60/50Hz operation: Two pole, Type C, 10A MCB
Proper Earthing must be provided. Also ensure that live phase is on right side
point of socket. It is strongly recommended to use a CVT of 1KVA capacity.
Neutral to Line Voltage should be 230VAC ±10% (for 230V operation)
Neutral to Line Voltage should be 110VAC ±10% (for 110V operation)
Neutral to Earth should be less than 3V AC
4.1.4.
TOOLS REQUIREMENTS
Provision of handling means such as Forklifts etc. is the owner's
responsibility
Following accessories and tools are required for the proper installation:
Screw drivers, Spanner set and Allen key set
Measurement Tape, 5mtr
Chalk liner/Marker pen
– For marking
Strip cutter
– to Open Carton banding
Knife
– For opening Cartons
Plastic cable ties
– for proper routing of cables
Multimeter
– For verifying supply voltage
Nylon Hammer
Hammer Drill and 12mm Drill bit
„U‟ type Shims (required quantities) – 0.5mmT & 1.0mmT
600
700
1720