Reddi-Arm Operator’s Manual
Page 39
Mandako Agri Marketing (2010) Ltd.
3.11.2 REMOVING FROM STORAGE:
When removing this unit from storage, follow this
procedure:
1. Clear the area of bystanders, especially small
children.
2. Attach the unit to the tractor (see Section 3.7).
3. Check:
a. Electrical harness connections and components.
b.
All hardware. Tighten as required.
c. Tire pressure. (see section 7.2)
d. All hydraulic lines, fittings and connections.
Tighten as required.
4. Lubricate all grease fittings as per section 4.2.
5. Clean rust inhibitor or grease from exposed cylinder
ram ends
6.
Replace any worn or defective parts.
7. Go through the pre-operation checklist (see Section
3.3) before using unit.