Wear protective gloves and protective glasses!
Wear proper protective clothing!
12.2 ELECTRICAL CONNECTIONS
Warning
Wrong supply voltage can damage the equipment. When connecting
the equipment, make sure the supply voltage is identical with the
information provided on the model type plate!
Note
For the erection of power installations with rated voltages up to 1000V,
the requirements of VDE 0100 and relevant standards and
specifications must be observed!
The main circuit is equipped with a fuse corresponding to the nominal
current (over current protection); for electrical details see technical
data.
The
PSS-5...
gas conditioning system is available with either 230 V/50 Hz or with 115 V/60 Hz (for circuit
diagram see Appendix). Fuse protection is provided by a 16 A circuit breaker as standard. Fuse
protection is provided by a 16 A circuit breaker as standard. This is located on the terminal support rail
of the housing (see Fig. 7).
For the electrical connection select the appropriate cable. Cable glands at the bottom of the SS-M0-5
are provided for the cables. The cable glands must be tightened after the cables have been inserted.
Note
Unused cable entries must be fitted with blind plugs to ensure IP
protection of the enclosure.
Summary of Contents for 03G6000
Page 44: ...44 SS M05_Marine 1 01 00 www mc techgroup com Figure 13 Wiring diagram part 1 ...
Page 45: ...www mc techgroup com SS M05_Marine 1 01 00 45 Figure 14 Wiring diagram part 2 ...
Page 46: ...46 SS M05_Marine 1 01 00 www mc techgroup com ...
Page 47: ...www mc techgroup com SS M05_Marine 1 01 00 47 ...
Page 48: ...48 SS M05_Marine 1 01 00 www mc techgroup com ...