MD-TJ42
Operation and Maintenance Manual
MD02-OMM-70-001
Issue: 06
Rev. 00
Rev. Date: 19.11.2018
Page 7-5
7.5 Component Change
Following parts can be replaced by the operator or owner of the
engine.
CAUTION:
Check if these tasks are covered by the
maintenance program (pilot owner authorization)
of the aircraft.
7.5.1
Glow Plug (Igniter)
(1)
Disconnect battery
(2)
Remove split pin
(3)
Disconnect wiring from glow plug
(4)
Remove igniter from glow plug retainer
(5)
Replace O-ring within glow plug retainer
(6)
Insert new glow plug
(7)
Insert split pin
(8)
Connect wiring to glow plug
(9) Connect battery
(10)
Perform engine ground test run (start engine once to
check whether the new glow plug functions correctly)
according to section 4.3
(11)
Check glow plug retainer for consistence
7.5.2
EGT-Sensor
(1)
Disconnect battery
(2)
Disconnect EGT-sensor wiring from the sensor board
(3)
Unscrew mounting clamp of EGT-sensor on engine
from engine
(4)
Loosen screw connection on the nozzle
(5)
Remove EGT-sensor
(6)
Attach new EGT-sensor to the nozzle