These technical specifications state a row of manufactured sizes and models of fire dampers (further only dampers) FDMS.
It is valid for production, designing, ordering, delivery, assembly and operation.
Description........................................................................................................................................................
2
Damper design..................................................................................................................................................
3
Communication and control devices.................................................................................................................
6
Dimensions and weights....................................................................................................................................
7
Placement and assembly..................................................................................................................................
8
Installations opening.........................................................................................................................................
9
Statement of installation....................................................................................................................................
9
Descriptions of particular installations...............................................................................................................
10
Pressure loss....................................................................................................................................................
21
Noise data.........................................................................................................................................................
22
Entry into service and revisions........................................................................…..............................................
26
In case of products with "P-mark" certification from RISE Institute in Sweden these technical specifications must be meet in
addition to the standard design:
■
In addition to activation by means of thermal fuses or links in the actuator, the damper must also be activated by smoke
detectors and/or heat detectors that have been installed in suitable positions.
■
The smoke and heat detectors used together with the fire damper must be designated and constructed in accordance with
one of the following standards EN 54-5, EN 54-7, EN 54-12 or EN 54-20.
■
The damper must be controlled by an actuator connected to a higher-level supervisory and constrol system.
■
Correct operation of the damper must be verified by automatic testing of its function at least once per 48 hours.
After reaching o these requirements the product will be provided with this certificate:
■
Certified body - RISE Certifiering.
■
Number of the certificate - SC1433-17.