Design with the communication and power supply unit

 

Design with the communication and power supply unit BKNE230-24 and the actuating mechanism
BLE24(BE24-12)-ST.

 

BKNE230-24 functions as a decentralized network device for supplying the actuating mechanism
BLE24(BE24-12)-ST on one hand and on the other hand it transmits signals from communication
and control device BKSE24-6.

  

It  simplifies  electrical  wiring  and  interconnection  of  dampers.  It  facilitates  on  site  check  and
enables  central  control  and  checks  of  fire  damper  by  means  of  a  simple  2-conductor  wiring.
 BKNE230-24  signals  the  damper  position  „OPEN“/„CLOSED“  (from  switches  on  the  actuator)
and  any  fault  alarms  to  the  BKSE24-6  unit.  It  also  receives  positioning  commands  from  the
control  unit  and  triggers  the  actuator  to  the  required  position.  The  last  control  command  is
retained troughout temporary power failures.

 

The BKNE230-24 unit monitors the positions of the switches on the actuator, its running time and
the exchange of data with the control and monitoring unit BKSE24-6. It also monitors the actuator
current and the power supply.  In  order  to  make  installation  as  simple  as  possible  the  smoke
extraction damper actuators ...-ST are fitted with plug connectors that can be inserted directly into
the BKNE230-24 unit.

 

The 2-wire conductor must be connected to screw terminals 6 and 7. It is recommended that a
fire alarm signal cable suitable for the application be used for the 2-wire conductor. It is essential

 

to ensure the correct polarity.

 

More information in catalogue Belimo.

Summary of Contents for SEDS-L

Page 1: ......

Page 2: ...for production designing ordering delivery maintenance and operation 1 Description 2 2 Design 3 3 Dimensions weights 8 4 Placement and Assembly 10 5 Pressure drops 12 6 Noise data 12 7 Material 14 8...

Page 3: ...applications according with EN 1366 9 The field of direct applications based on tests results is acceptable according to EN 1363 1 part A 1 and A 2 EN 1366 2 part 13 and EN 1366 10 part 9 Smoke extrac...

Page 4: ...r macroclimatic areas with mild climate according to EN 60 72133 Temperature in the place of installation is permitted to range from 20 C to 50 C Design with actuating mechanism SEDS L is equipped by...

Page 5: ...II II Degree of protection IP 54 Running time for 95 30 s Ambient temperature range Non operating temperature 30 C 50 C 40 C 80 C Connecting motor auxiliary switch cable 1 m 3 x 0 75 mm cable 1 m 6 x...

Page 6: ...imensioning 18 VA Imax 8 2 A 5 ms 15 VA Imax 7 9 A 5 ms Protection class III II Degree of protection IP 54 Running time for 95 60 s Ambient temperature range Non operating temperature 30 C 50 C 40 C 8...

Page 7: ...the BKSE24 6 unit It also receives positioning commands from the control unit and triggers the actuator to the required position The last control command is retained troughout temporary power failure...

Page 8: ...ed by the BKSE24 6 unit and evaluated individually All BKNE230 24 units are triggered simultaneously To BKSE24 6 can be connected max 6 BKNE230 24 Communication is via the 2 wire conductor Correct ope...

Page 9: ...consumption 3 5 W operating position Dimensioning 5 5 VA 18 VA Imax 6 4 A 2 5 ms Protection class III Degree of protection IP 20 Ambient temperature range 0 50 C Connecting screw terminals for cable 2...

Page 10: ...BE 5 44 5 0 3075 BE 5 38 5 0 1785 BE 5 47 0 0 3485 BE 6 41 6 0 1947 BE 6 50 9 0 3801 BE 6 43 6 0 2157 BE 6 53 4 0 4211 BE 1 15 9 0 0369 BLE 1 19 2 0 0653 BLE 2 18 3 0 0439 BLE 2 22 2 0 0777 BLE 2 19...

Page 11: ...0 4928 BE 4 63 2 0 6647 BE 4 56 7 0 5788 BE 4 67 4 0 7807 BE 5 62 5 0 6450 BE 5 74 5 0 8700 BE 5 66 0 0 7310 BE 5 78 7 0 9860 BE 6 71 8 0 7972 BE 6 85 8 1 0753 BE 6 75 4 0 8832 BE 6 90 0 1 1913 BE Smo...

Page 12: ...11 Installation examples Pozice 1 Damper hinge 2 Nut 3 Washer 4 Profile C 5 Washer C 6 Wall construction without fire resistance...

Page 13: ...63 68 68 67 65 62 48 57 65 70 70 69 67 64 50 w air velocity in the free cross section AxB i e before blades f frequency of octave band Sound power level corrected with filter A ps static pressure drop...

Page 14: ...67 65 62 48 w air velocity in the free cross section AxB i e before blades f frequency of octave band 13 21 26 26 25 23 20 6 21 29 34 34 33 31 28 14 28 36 41 41 40 38 35 21 34 42 47 47 46 44 41 27 38...

Page 15: ...re must be in the range from 5 C to 40 C and maximum relative humidity 80 Dampers must be protected against mechanic damages when transported and manipulated All effective safety standards and directi...

Page 16: ...case that dampers are found unable to serve for their function for any cause it must be clearly marked The operator is obliged to ensure that the damper is put into condition in which it is ready for...

Page 17: ...mechanism BLE24 BE24 12 54 with the communication and supply device BKNE 230 24 and actuating mechanism BLE24 BE24 12 ST 66 insulation inside of the blades I flanges with height 20 mm F WEIGHT kg Dob...

Page 18: ...reserves the right for innovations of the product For actual product information see www mandik com MAND K a s Dob sk 550 26724 Hostomice Czech Republic Tel 420 311 706 706 E Mail mandik mandik cz ww...

Reviews: