4. Assembly and Setup
4.1 Assembly
Inspection
Carefully inspect for signs of damage in transit. If equipment has been damaged in transit, notify the Freight
Forwarder immediately. M&R is not responsible for damage that occurs during transportation.
4.1.1 Site Preparation
The i-Image S unit is intended to be set up and installed by factory trained service technicians. Any moving of the
unit after installation and calibration may affect the printers quality. It is highly recommended the final position and
location of the machine be determined at the time of installation.
If unit is moved after it is initially setup, re-level for correct operation.
Location must be in a light safe environment, typically in the screen room, away from Power Washers and over
spray. The unit should also be placed away from any source of wind or breeze such as screen drying fans or
heavy traffic areas.
The i-Image S must be setup in a proper working environment. The humidity in the room the machine operates in
must be between 40% and 80%. The temperature in the room the machine operates in should be relatively
comfortable with the temperature not exceeding 85F.
4.1.2 Power Requirements
It is Very Important that the unit be connected to a dedicated electrical service. Any high amperage drawing
devices such as power washers and exposure units can have a direct adverse effect on the printers performance.
The unit is supplied with a standard line cord, however an electrical plug rated for the correct electrical service
must be installed by a licensed electrician. Plug line cord into the receptacle next to On/Off switch on the rear of
the unit.
IMPORTANT
: The printer system is designed to be powered up at all times, as maintenance functions
are performed at set intervals to keep the printheads at optimum operational status. Because certain
maintenance functions are performed on a continuous basis, an uninterrupted power supply (UPS) is
recommended.
IMPORTANT
: Do not plug other items into the same outlet as power fluctuations may cause printing
problems.
4.1.3 Network and Internet Connections
The unit should be supplied with an Ethernet connection to network with the art department. It is also
recommended to have internet access for the i-Image S to allow remote access for diagnosis and troubleshooting.
Have enough Ethernet cable to reach to the base of the unit and an internal IT support person on hand during the
installation.