12
M&R Companies 1N 372 Main St. Glen Ellyn, IL 60137 USA
Tel: +630-858-6101 Fax: +630-858-6134
V.062414
WARNING:
Never operate the unit when placed on its side. In this position, the Quartz
Heating Element filaments (1) compress and arcing results in premature failure of the element filament.
Always operate the unit with the Quartz Heating Elements in the horizontal (normal operating) position.
1.
The Quartz Heating Element has a female electrical connector at both ends (1). Hold the Quartz
Heating Element near both ends and push the female electrical connector onto the spring socket (2).
2.
Place the opposite end of the Quartz Heating Element on the spring socket (1) on the other side of the
Reflector Assembly. Allow the spring loaded pressure to hold it in position.
3.
Install the remaining Quartz Heating Elements as described in the previous steps.