background image

Copyright © 2007 Linear LLC 

228127 A

M&S Systems Brand

2-Year Limited Warranty

Linear LLC warrants its M&S Systems brand products to be free of defects for 2 years. 
The  warranty period begins on either (a) the date of purchase or installation date of this 
product, or (b) the date of closing on a new residence in which this product was originally 
installed.

The warranty extends to the original user of the product and to each subsequent owner 
of the product during the term of the warranty. Linear will repair or replace, at its option, 
parts and materials at no charge. Parts supplied under this warranty may be new or 
rebuilt at the option of Linear.

If, during the warranty period, the product appears to have a defect, please call our 
toll free number (800-421-1587) prior to dismantling. Dismantling the product prior to 
calling our service number may void the warranty. Before returning any product to Linear, 
obtain a Return Product Authorization (RPA) number from our service department. 
Linear will return the repaired product freight prepaid within the continental United 
States. ANY PRODUCT RETURNED TO LINEAR WITHOUT AN RPA NUMBER WILL 
BE REFUSED.

This limited warranty is in lieu of any other warranties, express or implied, including any 
implied warranty of merchantability or fitness for a particular purpose or  otherwise, and 
of any other obligations or liability on the seller’s part. This limited warranty does not 
cover damage caused by improper installation, acts of God, criminal acts, the violation 
of applicable building or electrical codes or the use of non-M&S wire or cable (excluding 
CAT-5 and RG-6).

Under no circumstances shall Linear be liable for consequential, incidental or special 
damages arising in connection with use, or inability to use this product. In no event shall 
Linear’s liability hereunder exceed the cost of the product covered hereby. No person is 
authorized to assume for us or obligate us for any other liability in connection with the 
sale of this product. Some states do not allow the exclusion or limitation of consequential, 
incidental or special damages, so the above limitation or exclusion may not apply to you. 
This limited warranty gives you specific legal rights, and you may also have other rights, 
which vary from state to state.

www.mssystems.com

D

OOR RELEASE RELAY

The dmc1 master contains a dry contact relay that can be 
used to control external devices. Typical applications include 
activating a door strike, triggering a panic alarm system, or 
controlling a home automation or lighting system.

The door release relay has normally open contacts that 
are rated at 2 Amps @ 24 Volts AC/DC. The relay can 
be activated from the dmc1 master or remote scan room 
stations (Model dmc1RS) by pressing the volume up and 
volume down buttons together for four seconds. The relay 
will deactivate when the buttons are released.

Refer to the following steps for connecting a Model DRW 
Door Release Mechanism. For controlling other devices, 
refer to the hook-up instructions supplied with the device.

Route PBVM127X1 cable from the dmc1 master’s 
wall housing to the door release location.

Route PBVM127X1 cable from the dmc1 master’s wall 
housing to a location for a Model RT11 Remote Transformer. 
The transformer plugs into a standard 120 VAC outlet.

Route the two cables into the master’s wall housing 
through the top left wiring access hole or slot. Leave about 
12” of extra cable extending at the wall housing.

Zip-tie the two cables together and 

LABEL 

THE CABLES

 

“Door Release”

.

1.

2.

3.

4.

MODEL RT11

PLUG-IN

TRAN

S

FORMER

PBVM127X1

CABLE

MODEL DRW

ELECTRIC

DOOR 

S

TRIKE

REAR OF DMC1 MA

S

TER

DOOR RELEA

S

E

TERMINAL

S

Figure 13. Door Release Wiring

Summary of Contents for dmc1 Finish-Out

Page 1: ...ventilation openings Heat The appliance should be situated away from heat sources such as radiators heat registers stoves or other appliances including amplifiers that produce heat Power Sources The a...

Page 2: ...interference DO NOT exert more than 25 pounds of tension on 4 pair cables DO NOT step on Cat 5 cable during installation DO NOT overtighten the cable ties apply cable ties loosely with random spacing...

Page 3: ...1HKIT kit includes One metal wall housing for dmc1 One ME3 Door Station Enclosure One dmc1HRW Flush mount Rough in Enclosure Four dmc1HR Rough in Rings One FM Dipole Antenna 25 feet of AM Antenna Wire...

Page 4: ...an end of the cable into each of the transformer enclosures through the bottom knockout holes Use wire nuts to connect the cable to the TE2D transformer BLACK HOT and WHITE NEUTRAL input wires Connect...

Page 5: ...screw mounting the wires outstretched Fish the connector end of the antenna coax down through the hole in the ceiling plate down the stud bay and into the hole on the top right side of the wall housin...

Page 6: ...o surface mount intercom door station enclosures models are available Model DS3BXB black and DS3BXW white Surface mount enclosures attach to the finished wall using galvanized screws see Figure 8 Brin...

Page 7: ...ifier STEREO MUSIC SPEAKERS 45 ohm speakers for the stereo upgrade can be connected to the optional MC960PA amplifier to distribute radio or CD sound throughout the installation Each stereo speaker pa...

Page 8: ...h use or inability to use this product In no event shall Linear s liability hereunder exceed the cost of the product covered hereby No person is authorized to assume for us or obligate us for any othe...