background image

4

NOTE: VMC1 does not distinguish between audio from a room being monitored and 

audio from the tuner.  If a room is to be monitored, it is recommended that the 
tuner be turned off.

Set Volume Level at Master Station

To change the speaker volume at the Master Station:
1.  Turn Radio ON to provide an audio source
2.  Press MUS button to activate speaker at the Master Station
3.  Press  (plus) or Volume –  (minus) buttons to adjust level

Setting Volume Levels at Room Stations:

To change the speaker volume at any Room Station:

1.  Press the  or Volume – buttons

 to adjust level 

Room station will emit a steady tone increasing or decreasing in level 
depending on the button being pressed. 
This tone eliminates the need to have 
an audio source active at the Master 
Station while setting the desired volume 
level.  

Your installer may disable this tone at 
each room station, however doing so 
will require an active audio source at 
the Master Unit to set the volume levels.  If this is disabled, follow the 
steps under Setting the Volume Level at the Master Station to set the 
volume levels at the Room Stations. 

Privacy 

Press PRIV

 button to disable microphone 

This prevents any audio from transmitting. The Station continues to 
receive calls, however.

Point-To-Point and Whole House pages.

Page any Station where Privacy is active by following the 
Room-To-Room or Whole House Paging instructions.

Answer Calls in Privacy Mode:

1.  Press and release PRIV button

 to speak.  Station now functions 

normally.  

2.  Press and release the PRIV button again 

to end conversation.

Station remains in Privacy mode until disabled. 

3.  Press the PRIV button 

to disable Privacy Mode. 

Quick Start Guide: Music & Audio

VOLUME

+ (higher)

__ (lower)

PLUS +  &  MINUS  -  

Summary of Contents for VMC1

Page 1: ...C1 Video Security Intercom Music System Quick Start Guide USA Canada 800 421 1587 800 392 0123 760 438 7000 Toll Free FAX 800 468 1340 www linearcorp com VMC1 Video Security Intercom system for the ho...

Page 2: ...DO NOT expose the VMC1 to moisture or fire or shock hazards can occur and impair the warranty DO NOT expose Stations to direct water spray or damage will occur DO NOT attempt to service this product y...

Page 3: ...Start Guide Clock Radio 6 Master Station Video Display Operation 7 Quick Start Guide Video 7 NightStand Station Audio Input 8 Help Menu 8 Optional Functions 8 Quick Start Guide Options 8 Master Statio...

Page 4: ...y he programmed for a single digit or double digit ID If you have more than seven 7 interior Stations including the Master or use AUX OUTPUTS from a Nightstand Station your system should be programmed...

Page 5: ...To end the conversation press CLEAR 5 System times out after 20 seconds after pressing the last button press RED Status LED turns OFF Other Intercom Functions Listen to Music or access Audio Monitor I...

Page 6: ...aster Station while setting the desired volume level Your installer may disable this tone at each room station however doing so will require an active audio source at the Master Unit to set the volume...

Page 7: ...imply press that button 4 Press and release the 5 button and then select a button from 1 to 5 to select location 6 to 10 For example pressing 5 and 1 will save the station in location 6 5 Press MEM to...

Page 8: ...re MUS is active will the music be heard If the Radio is on and the selected Alarm time is reached the Radio will turn off Radio Filter To reduce background noise or radio interference on the radio th...

Page 9: ...e If a Video Door Station chime is activated the Master Station Video display is active that door station camera will display on the Master Station video display for 20 seconds then revert to the prev...

Page 10: ...the volume from the NightStand Station is at the desired level NOTE With the switch positioned towards the center of the Station the NightStand Station will not play any music from the Master Station...

Page 11: ...5 The visitor responds hands free 6 Press LOCK button to activate electronic door release Door lock remains open for four 4 seconds and then locks NOTE Press LOCK again to reopen as long as the commun...

Page 12: ...rbell as well as see them Initial Power Up When you power up the master station displays a blue welcome screen showing the applicable software version 1 Press CLEAR to clear screen Enter Program Mode...

Page 13: ...7 VID 1 2 3 Displays Video Displays Door Video Cam 4 Speaker Volume Keys See 6 Radio Output Monitored Room Output 5 Intercom Keypad See Table 2 6 Volume controls Plus Minus keypad buttons 7 LED Indic...

Page 14: ...ume at Master for Radio and Intercom Program Mode Number Keys 1 7 Station ID Aux 1 Auxilliary Function Aux 2 FILTER Input Filter Arrow Up LOCK LOCK Unlocks Door Arrow Down PRIV Privacy control MON Mon...

Page 15: ...Auxiliary music input source selected RADIO FILTER Steady Green Radio filter on DOOR STATUS Steady Red Door is open AUX OUTPUT 1 Steady Yellow Auxiliary relay 1 activated AUX OUTPUT 1 Steady Yellow A...

Page 16: ...reinstallation ANY PRODUCT RETURNED TO LINEAR LLC WITHOUT A RPA NUMBER WILL BE REFUSED This limited warranty is in lieu of any other warranties express or implied including any implied warranty of mer...

Reviews: