background image

1

warranty inforMation 

 

Coverage

 

For the original purchaser of this MANHATTAN Uninterruptible Power Supply residing in the United States or 

Canada, the device itself features a lifetime warranty covering material and workmanship (with a three-year 

warranty on the battery). Should the UPS fail, it will either be repaired or replaced (manufacturer’s option). 
Should UC-, UL-, CSA- or CE-listed electronic equipment connected to the MANHATTAN Uninterruptible 

Power Supply be damaged by power or phone line transients such as spikes or surges, the manufacturer has 

the option of repairing or replacing the damaged equipment or keeping the damaged equipment and paying 

fair market value for it (not to exceed a total of $100,000).
This warranty does 

not

 cover a) damage caused by improper installation, repairs, servicing or alterations; b) 

damage due to the improper packing or shipping of items returned to the manufacturer; c) damage to electronic 

equipment that is not UC-, UL-, CSA- or CE-listed; d) damage to UC-, UL-, CSA- or CE-listed equipment not caused 

by power or phone line transients such as spikes or surges; e) damage caused by a failure to use properly wired 

and grounded electrical outlets, telephone service and, if applicable, cable TV service; f) damage caused by a 

failure to install primary protection devices for power and telephone service equipment; g) damage caused by 

cable TV transients; or h) damage caused during any use of this device for which it was not intended.

Note:

 Some states do not allow the exclusion or limitation of incidental or consequential damages, which means 

the above may not apply. This warranty gives you specific legal rights. You may also have other rights, which 

vary from state to state.

 

Implied Warranty

 

Implied warranties, including the implied warranty of merchantability and the implied warranty of fitness for 

 

Summary of Contents for 168120

Page 1: ...MAN 168120 168175 UM 0606 06 line interactive uninterruptible power supply USER MANUAL MODEL 168120 168175...

Page 2: ...ose operations Among the main features Advanced protection for PC and Macintosh systems against power outages sags surges and line noise Built in microprocessor maintains proper charge provides consis...

Page 3: ...acing the battery Do not dispose of the battery in a fire as the battery may explode Do not open or mutilate the battery as it contains a toxic electrolyte harmful to both the skin and eyes Proper dis...

Page 4: ...ree pronged plug The UPS must be plugged into a two pole three wire grounding receptacle If an extension cord must be used use a three wire grounding type rated at least 8 Amps Plug the UPS into a two...

Page 5: ...t is important that the total power needs of the equipment not exceed the capacity of the UPS The UPS will emit a loud tone and the yellow LED will illuminate to alert you of an overload Consult your...

Page 6: ...nal power source The UPS will emit a loud tone before it shuts down and ceases to power your equipment The yellow LED will be illuminated and stay on to alert you of the overload until the UPS is star...

Page 7: ...Replace Battery LED The LED lights when the UPS detects that the battery needs to be replaced soon Charge the UPS at least four hours If the LED lights again after charging the battery might need rep...

Page 8: ...cords to connect the UPS to the power source 7 Surge Protection Bypass Outlets These protect against surges and spikes 8 Battery Backup Surge Protection Outlets These provide emergency battery backup...

Page 9: ...ase T surge protection NOTE This connection is not needed to use the UPS indicator table The UPS has both visible LED and audible alarm status indicators The LED numbers correspond to the Indicator im...

Page 10: ...EDs are lit and Internal UPS system fault Return the UPS for service the UPS is emitting a constant tone The UPS doesn t provide The battery is not fully charged Remove all connected equipment from th...

Page 11: ...ne fax network ports RJ 11 RJ 45 1 in 1 out surge protected Nominal voltage input 100 V 110 V 120 V 220 V 230 V 240 V output 120 V 230 V Voltage range input 96 V 138 V 174 V 262 V Frequency range inpu...

Page 12: ...175 Outlets 5 NEMA 120 V 4 backup surge 1 surge only 3 IEC 22O V 3 backup surge Times Backup 5 minutes at full load 12 minutes at 50 load 35 minutes at varying loads typical with PC and 15 LCD monitor...

Page 13: ...ity 12 V 5 Ah x 2 type sealed and maintenance free lead acid Temperatures C operation 0 to 40 storage 20 to 60 Operation relative humidity 0 to 95 non condensing LED indicators Online Overload On Batt...

Page 14: ...ations b damage due to the improper packing or shipping of items returned to the manufacturer c damage to electronic equipment that is not UC UL CSA or CE listed d damage to UC UL CSA or CE listed equ...

Page 15: ...he original purchaser no longer owns the product and three years from the date of purchase for the battery Note Some states do not allow time limitations on implied warranties which means the above li...

Page 16: ...rademarks or registered trademarks of their respective owners www manhattan products com MANHATTAN offers a complete line of PC Components Peripherals Cables and Accessories Ask your local computer de...