Thank you for purchasing the MANHATTAN

®

 Line Interactive Uninterruptible Power Supply, Model 

168120 or 168175. This uninterruptible power supply (UPS) is designed to keep computers and 

peripheral devices operating after a utility power failure that could result in component damage or loss of 

data. Whenever the UPS is plugged in, it maintains a full charge on its battery and serves to protect your 

equipment from utility-generated surges and noise. It also provides visual and audible indicators that alert 

you to utility line failures, giving you ample time to save files and close operations. Among the main features: 

 

• Advanced protection for PC and Macintosh systems against power outages, sags, surges and line noise 

• Built-in microprocessor maintains proper charge, provides consistent power output and helps extend 

  battery life 

• Automatic voltage regulation (AVR), cold start capability and diagnostics 

• 480 Joules telephone, fax and network surge protection 

• Fuse protection from overload and short circuit events 

• LED and audible alert system and power management software help monitor critical functions 

• $100,000 connected equipment guarantee (US and Canada only) 

• Lifetime Warranty, UPS; Three-year Warranty, battery 

 

Package contents: 

• Line Interactive UPS Model 168120 (500 VA / 300 W) or Model 168175 (1000 VA / 600 W) 

• UPS Monitor Software CD 

• Connecting Cables 

• User Manual

 

 

 

Summary of Contents for 168120

Page 1: ...MAN 168120 168175 UM 0606 06 line interactive uninterruptible power supply USER MANUAL MODEL 168120 168175...

Page 2: ...ose operations Among the main features Advanced protection for PC and Macintosh systems against power outages sags surges and line noise Built in microprocessor maintains proper charge provides consis...

Page 3: ...acing the battery Do not dispose of the battery in a fire as the battery may explode Do not open or mutilate the battery as it contains a toxic electrolyte harmful to both the skin and eyes Proper dis...

Page 4: ...ree pronged plug The UPS must be plugged into a two pole three wire grounding receptacle If an extension cord must be used use a three wire grounding type rated at least 8 Amps Plug the UPS into a two...

Page 5: ...t is important that the total power needs of the equipment not exceed the capacity of the UPS The UPS will emit a loud tone and the yellow LED will illuminate to alert you of an overload Consult your...

Page 6: ...nal power source The UPS will emit a loud tone before it shuts down and ceases to power your equipment The yellow LED will be illuminated and stay on to alert you of the overload until the UPS is star...

Page 7: ...Replace Battery LED The LED lights when the UPS detects that the battery needs to be replaced soon Charge the UPS at least four hours If the LED lights again after charging the battery might need rep...

Page 8: ...cords to connect the UPS to the power source 7 Surge Protection Bypass Outlets These protect against surges and spikes 8 Battery Backup Surge Protection Outlets These provide emergency battery backup...

Page 9: ...ase T surge protection NOTE This connection is not needed to use the UPS indicator table The UPS has both visible LED and audible alarm status indicators The LED numbers correspond to the Indicator im...

Page 10: ...EDs are lit and Internal UPS system fault Return the UPS for service the UPS is emitting a constant tone The UPS doesn t provide The battery is not fully charged Remove all connected equipment from th...

Page 11: ...ne fax network ports RJ 11 RJ 45 1 in 1 out surge protected Nominal voltage input 100 V 110 V 120 V 220 V 230 V 240 V output 120 V 230 V Voltage range input 96 V 138 V 174 V 262 V Frequency range inpu...

Page 12: ...175 Outlets 5 NEMA 120 V 4 backup surge 1 surge only 3 IEC 22O V 3 backup surge Times Backup 5 minutes at full load 12 minutes at 50 load 35 minutes at varying loads typical with PC and 15 LCD monitor...

Page 13: ...ity 12 V 5 Ah x 2 type sealed and maintenance free lead acid Temperatures C operation 0 to 40 storage 20 to 60 Operation relative humidity 0 to 95 non condensing LED indicators Online Overload On Batt...

Page 14: ...ations b damage due to the improper packing or shipping of items returned to the manufacturer c damage to electronic equipment that is not UC UL CSA or CE listed d damage to UC UL CSA or CE listed equ...

Page 15: ...he original purchaser no longer owns the product and three years from the date of purchase for the battery Note Some states do not allow time limitations on implied warranties which means the above li...

Page 16: ...rademarks or registered trademarks of their respective owners www manhattan products com MANHATTAN offers a complete line of PC Components Peripherals Cables and Accessories Ask your local computer de...